Repository logo
Log in(current)
Repository logoMIT Open ScholarshipDSpace@MIT
  1. Home
  2. MIT Open Access Articles
  3. MIT Open Access Articles
  4. Blood flow measurement and slow flow detection in retinal vessels with Joint Spectral and Time domain method in ultrahigh speed OCT

Blood flow measurement and slow flow detection in retinal vessels with Joint Spectral and Time domain method in ultrahigh speed OCT

Thumbnail Image
Download
Name

Fujimoto-Blood flow.pdf

Size

1.91 MB

Format

Adobe PDF

Checksum (MD5)

0d69e235b058b27774e6585cf0bb8c58

Author(s)
Gorczynska, Iwona
•
Szkulmowski, M.
•
Grulkowski, Ireneusz
•
Szkulmowska, A.
•
Szlag, D.
•
Fujimoto, James G.
•
Kowalczyk, Andrzej
•
Wojtkowski, M.
Date Issued
January 2010
Journal
Proceedings of SPIE--the International Society for Optical Engineering; v.7550
Publisher
SPIE
Citation
Gorczynska, I. et al. “Blood Flow Measurement and Slow Flow Detection in Retinal Vessels with Joint Spectral and Time Domain Method in Ultrahigh-speed OCT.” Proc. SPIE 7550 75501Y-7 (2010). © 2010 Copyright SPIE
Version
Final published version
Abstract
We present an application of the Joint Spectral and Time domain OCT (STdOCT) method for detection of wide range of flows in the retinal vessels. We utilized spectral/Fourier domain OCT (SOCT) technique for development of scan protocols for Doppler signal analysis. We performed retinal imaging in normal eyes using ultrahigh speed (200 000 axial scans/s) SOCT instrument with a CMOS camera. Various raster scan protocols were implemented for investigation of blood flow in the retina. Data analysis was performed using the method of joint Spectral and Time domain OCT (STdOCT). Detection of blood flow velocities ranging from several tens of mm/s to a fraction of mm/s was possible with scanning methods allowing for appropriate selection of time intervals between data taken for Doppler OCT analysis. Axial blood flow velocity measurement was possible in retinal vessels. Doppler OCT signal can be utilized as a contrast mechanism for visualization of retinal capillaries.
MIT Department
Massachusetts Institute of Technology. Department of Electrical Engineering and Computer Science
Massachusetts Institute of Technology. Research Laboratory of Electronics
Terms of Use
Article is made available in accordance with the publisher's policy and may be subject to US copyright law. Please refer to the publisher's site for terms of use.
Persistent DSpace Link
http://hdl.handle.net/1721.1/72159
DOI of Published Version
https://doi.org/10.1117/12.840020
Repository logo
PrivacyPermissionsAccessibilityContact us
Repository logo
Notify us about copyright concerns.