Performance of CMS hadron calorimeter timing and synchronization using test beam, cosmic ray, and LHC beam data
Name
0911.4877.pdf
Description
Submitted version
Size
456.26 KB
Format
Adobe PDF
Checksum (MD5)
9c100b8838c30738ca979dc6f76e8ab0
Author(s) • • • • • • • • •
Alver, Burak Han
Bauer, Gerry P
Bendavid, Joshua L.
Busza, Wit
Butz, Erik M.
Cali, Ivan Amos
Chan, M.
D'Enterria, David
Everaerts, Pieter Bruno Bart
Gomez-Ceballos, Guillelmo
Date Issued
March 2010
Journal
Journal of Instrumentation
Publisher
IOP Publishing
Citation
Chatrchyan, S. et al. "Performance of CMS hadron calorimeter timing and synchronization using test beam, cosmic ray, and LHC beam data." Journal of Instrumentation 5 (March 2010): T03013 © 2010 IOP Publishing Ltd and SISSA
Version
Original manuscript
Abstract
This paper discusses the design and performance of the time measurement technique and of the synchronization systems of the CMS hadron calorimeter. Time measurement performance results are presented from test beam data taken in the years 2004 and 2006. For hadronic showers of energy greater than 100 GeV, the timing resolution is measured to be about 1.2 ns. Time synchronization and out-of-time background rejection results are presented from the Cosmic Run At Four Tesla and LHC beam runs taken in the Autumn of 2008. The inter-channel synchronization is measured to be within 2 ns.
MIT Department
Massachusetts Institute of Technology. Department of Physics
Massachusetts Institute of Technology. Department of Nuclear Science and Engineering
Massachusetts Institute of Technology. Laboratory for Nuclear Science
Terms of Use
Creative Commons Attribution-Noncommercial-Share Alike
Persistent DSpace Link
DOI of Published Version
https://doi.org/10.1088/1748-0221/5/03/T03013