Control of underactuated fluid-body systems with real-time particle image velocimetry
Name
815793047-MIT.pdf
Description
Full printable version
Size
17.32 MB
Format
Adobe PDF
Checksum (MD5)
29bb0f0b8a3d36926958aa1883760553
Author(s)
Roberts, John W., Ph. D. Massachusetts Institute of Technology
Advisor(s)
Russ Tedrake.
Date Issued
2012
Publisher
Massachusetts Institute of Technology
Abstract
Controlling the interaction of a robot with a fluid, particularly when the desired behavior is intimately related to the dynamics of the fluid, is a difficult and important problem. High-performance aircraft cannot ignore nonlinear stall effects, and robots hoping to fly and swim with performance matching that seen in birds and fish cannot treat fluid flows as quasi-steady. If we wish to match the level of performance seen in nature several major hurdles must be overcome, with one of the most difficult being the poor observability of the fluid state. Fluid dynamicists have long contended with this observability problem, and have used computationally intensive Particle Image Velocimetry (PIV) to gain an understanding of the fluid behavior after the fact. However, improvement in available computational power is now making it possible to perform PIV in real-time. When PIV provides real-time awareness of the fluid state it is no longer just an analysis tool, but rather a valuable sensor that can be integrated into the control loop. In this thesis I present methods for controlling fluid-body systems in which the fluid plays a vital dynamical role, for performing real-time PIV, and for interpreting the output of PIV in a manner useful to control. The utility of these methods is demonstrated on a mechanically simple but dynamically rich experimental platform: the hydrodynamic cartpole. This system is analogous to the well-known cart-pole system in the controls literature, but through its relationship with the surrounding fluid it captures many of the fundamental challenges of general fluid-body control tasks, including: nonlinearity, underactuation, an important and unknown fluid state and a dearth of accurate and tractable models. The first complete demonstration of closed-loop PIV control is performed on this system, and there is a statistically significant improvement in the system's ability to reject fluid disturbances when using real-time PIV for closed-loop control. These results suggest that these new techniques will push the boundaries of what we can expect a robot in a fluid to do.
Description
Thesis (Ph. D.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 2012.
Cataloged from PDF version of thesis.
Includes bibliographical references (p. 141-153).
Subjects
Mechanical Engineering.
MIT Department
Massachusetts Institute of Technology. Department of Mechanical Engineering
Terms of Use
M.I.T. theses are protected by
copyright. They may be viewed from this source for any purpose, but
reproduction or distribution in any format is prohibited without written
permission. See provided URL for inquiries about permission.
copyright. They may be viewed from this source for any purpose, but
reproduction or distribution in any format is prohibited without written
permission. See provided URL for inquiries about permission.
Persistent DSpace Link