Repository logo
Log in(current)
Repository logoMIT Open ScholarshipDSpace@MIT
  1. Home
  2. MIT Open Access Articles
  3. MIT Open Access Articles
  4. Calibrating genomic and allelic coverage bias in single-cell sequencing

Calibrating genomic and allelic coverage bias in single-cell sequencing

Thumbnail Image
Download
Name

44800_2_merged_1425397101.pdf

Size

702.69 KB

Format

Adobe PDF

Checksum (MD5)

17bee5eb4d8bdd135c81237341bde8d1

Author(s)
Zhang, Cheng-Zhong
•
Francis, Joshua
•
Cornils, Hauke
•
Jung, Joonil
•
Maire, Cecile
•
Ligon, Keith L.
•
Meyerson, Matthew
•
Adalsteinsson, Viktor A.
•
Love, John C
Date Issued
April 2015
Journal
Nature Communications
Publisher
Nature Publishing Group
Citation
Zhang, Cheng-Zhong et al. “Calibrating Genomic and Allelic Coverage Bias in Single-Cell Sequencing.” Nature Communications 6 (April 2015): 6822 © 2015 Macmillan Publishers Limited
Version
Author's final manuscript
Abstract
Artifacts introduced in whole-genome amplification (WGA) make it difficult to derive accurate genomic information from single-cell genomes and require different analytical strategies from bulk genome analysis. Here, we describe statistical methods to quantitatively assess the amplification bias resulting from whole-genome amplification of single-cell genomic DNA. Analysis of single-cell DNA libraries generated by different technologies revealed universal features of the genome coverage bias predominantly generated at the amplicon level (1–10 kb). The magnitude of coverage bias can be accurately calibrated from low-pass sequencing (∼0.1 × ) to predict the depth-of-coverage yield of single-cell DNA libraries sequenced at arbitrary depths. We further provide a benchmark comparison of single-cell libraries generated by multi-strand displacement amplification (MDA) and multiple annealing and looping-based amplification cycles (MALBAC). Finally, we develop statistical models to calibrate allelic bias in single-cell whole-genome amplification and demonstrate a census-based strategy for efficient and accurate variant detection from low-input biopsy samples.
MIT Department
Massachusetts Institute of Technology. Department of Chemical Engineering
Koch Institute for Integrative Cancer Research at MIT
Terms of Use
Article is made available in accordance with the publisher's policy and may be subject to US copyright law. Please refer to the publisher's site for terms of use.
Persistent DSpace Link
http://hdl.handle.net/1721.1/111665
DOI of Published Version
https://doi.org/10.1038/ncomms7822
Repository logo
PrivacyPermissionsAccessibilityContact us
Repository logo
Notify us about copyright concerns.