Surface Plasmon‐Enhanced Short‐Wave Infrared Fluorescence for Detecting Sub‐Millimeter‐Sized Tumors
Name
10.1002-adma.202006057.pdf
Size
1.13 MB
Format
Unknown
Checksum (MD5)
8f9cd9374d703a1bd7b28f9ff9ce1b32
Author(s) • • • • • • • • •
Huang, Shengnan
Lin, Ching‐Wei
Qi, Jifa
Iyer, Archana Mahadevan
He, Yanpu
Li, Yingzhong
Bardhan, Neelkanth M.
Irvine, Darrell J.
Hammond, Paula T.
Belcher, Angela M.
Date Issued
January 2021
Journal
Advanced Materials
Publisher
Wiley
Citation
Huang, Shengnan, Lin, Ching‐Wei, Qi, Jifa, Iyer, Archana Mahadevan, He, Yanpu et al. 2021. "Surface Plasmon‐Enhanced Short‐Wave Infrared Fluorescence for Detecting Sub‐Millimeter‐Sized Tumors." Advanced Materials, 33 (7).
Version
Author's final manuscript
Abstract
Short-wave infrared (SWIR, 900–1700 nm) enables in vivo imaging with high spatiotemporal resolution and penetration depth due to the reduced tissue autofluorescence and decreased photon scattering at long wavelengths. Although small organic SWIR dye molecules have excellent biocompatibility, they have been rarely exploited as compared to their inorganic counterparts, mainly due to their low quantum yield. To increase their brightness, in this work, the SWIR dye molecules are placed in close proximity to gold nanorods (AuNRs) for surface plasmon-enhanced emission. The fluorescence enhancement is optimized by controlling the dye-to-AuNR number ratio and up to ≈45-fold enhancement factor is achieved. In addition, the results indicate that the highest dye-to-AuNR number ratio gives the highest emission intensity per weight and this is used for synthesizing SWIR imaging probes using layer-by-layer (LbL) technique with polymer coating protection. Then, the SWIR imaging probes are applied for in vivo imaging of ovarian cancer and the surface coating effect on intratumor distribution of the imaging probes is investigated in two orthotopic ovarian cancer models. Lastly, it is demonstrated that the plasmon-enhanced SWIR imaging probe has great potential for fluorescence imaging-guided surgery by showing its capability to detect sub-millimeter-sized tumors.
MIT Department
Massachusetts Institute of Technology. Department of Materials Science and Engineering
Koch Institute for Integrative Cancer Research at MIT
Massachusetts Institute of Technology. Department of Biological Engineering
Massachusetts Institute of Technology. Department of Chemical Engineering
Terms of Use
Creative Commons Attribution-Noncommercial-Share Alike
Persistent DSpace Link
DOI of Published Version
https://doi.org/10.1002/adma.202006057