Repository logo
Log in(current)
Repository logoMIT Open ScholarshipDSpace@MIT
  1. Home
  2. MIT Open Access Articles
  3. MIT Open Access Articles
  4. Continuous-Flow Bioseparation Using Microfabricated Anisotropic Nanofluidic Sieving Structures

Continuous-Flow Bioseparation Using Microfabricated Anisotropic Nanofluidic Sieving Structures

Thumbnail Image
Download
Name

Han_Continuous Flow.pdf

Size

1017.19 KB

Format

Adobe PDF

Checksum (MD5)

8177b013a63e66ddbe1622c023906a01

Author(s)
Fu, Jianping
•
Mao, Pan
•
Han, Jongyoon
Date Issued
October 2009
Journal
Nature Protocols
Publisher
Nature Publishing Group
Citation
Fu, Jianping, Pan Mao and Jongyoon Han. "Continuous-Flow Bioseparation Using Microfabricated Anisotropic Nanofluidic Sieving Structures." Nature Protocols. v.4:no.11, p.1681-1698. © 2009 Nature Publishing Group.
Version
Author's final manuscript
Abstract
The anisotropic nanofluidic-filter (nanofilter) array (ANAANAANA) is a unique molecular-sieving structure for separating biomolecules. In this protocol we describe the fabrication of planar and vertical ANAANAANA chips and how to perform continuous-flow bioseparation using them. This protocol is most useful for bioengineers who are interested in developing automated multistep chip-based bioanalysis systems and assumes previous cleanroom microfabrication knowledge. The ANAANAANA consists of a two-dimensional periodic nanofilter array, and the designed structural anisotropy of ANAANAANA causes different-sized or charged biomolecules to follow distinct trajectories under applied electric fields, leading to efficient continuous-flow separation. Using microfluidic channels surrounding the ANAANAANA, the fractionated biomolecule streams are collected and routed to different fluid channels or reservoirs for convenient sample recovery and downstream bioanalysis. The ANAANAANA is physically robust and can be reused repeatedly. Compared with the conventional gel-based separation techniques, ANAANAANA offers the potential for faster separation, higher throughput and more convenient sample recovery.
MIT Department
Massachusetts Institute of Technology. Department of Electrical Engineering and Computer Science
Massachusetts Institute of Technology. Department of Mechanical Engineering
Massachusetts Institute of Technology. Research Laboratory of Electronics
Terms of Use
Article is made available in accordance with the publisher's policy and may be subject to US copyright law. Please refer to the publisher's site for terms of use.
Persistent DSpace Link
http://hdl.handle.net/1721.1/55958
DOI of Published Version
https://doi.org/10.1038/nprot.2009.176
Repository logo
PrivacyPermissionsAccessibilityContact us
Repository logo
Notify us about copyright concerns.