Distributed Live Muscle Actuators Controlled by Optical Stimuli
Name
v01at02a007-sbc2013-14851.pdf
Size
867.82 KB
Format
Adobe PDF
Checksum (MD5)
7578fd23f586c59053f223bc9440d816
Author(s) • •
Sakar, Mahmut Selman
Neal, Devin M
Asada, Haruhiko
Date Issued
June 2013
Journal
ASME 2013 Summer Bioengineering Conference
Publisher
ASME International
Citation
Neal, Devin, et al. “Distributed Live Muscle Actuators Controlled by Optical Stimuli.” ASME 2013 Summer Bioengineering Conference, 26-29 June, 2013, Sunriver, Oregon, ASME, 2013, p. V01AT02A007. © 2013 by ASME
Version
Final published version
Abstract
A multi degree of freedom skeletal muscle system stimulated via optical control is presented. These millimeter-scale, optically excitable 3D skeletal muscle bio-actuators are created by culturing genetically modified precursory muscle cells that are activated with light: optogenetics. These muscle bio-actuators are networked together to create a distributed muscle system. Muscle systems can manipulate loads having no fixed joint. These types of loads include shoulders, the mouth, and the jaw. Topics: Actuators , Muscle
MIT Department
Massachusetts Institute of Technology. Department of Mechanical Engineering
Terms of Use
Article is made available in accordance with the publisher's policy and may be subject to US copyright law. Please refer to the publisher's site for terms of use.