Repository logo
Log in(current)
Repository logoMIT Open ScholarshipDSpace@MIT
  1. Home
  2. MIT Open Access Articles
  3. MIT Open Access Articles
  4. Stochastic Estimation of the Multi-Variable Mechanical Impedance of the Human Ankle With Active Muscles

Stochastic Estimation of the Multi-Variable Mechanical Impedance of the Human Ankle With Active Muscles

Thumbnail Image
Download
Name

429_1.pdf

Size

141.95 KB

Format

Adobe PDF

Checksum (MD5)

b6485618788d0970584788d137e69d43

Download all files submitted through automated deposit
sword-2018-11-30.original.zip (128.94 KB)
Author(s)
Rastgaar Aagaah, Mohammad
•
Ho, Patrick
•
Lee, Hyunglae
•
Krebs, Hermano I
•
Hogan, Neville
Date Issued
September 2010
Journal
ASME 2010 Dynamic Systems and Control Conference, Volume 1
Publisher
ASME International
Citation
Rastgaar, Mohammad A., Patrick Ho, Hyunglae Lee, Hermano Igo Krebs, and Neville Hogan. “Stochastic Estimation of the Multi-Variable Mechanical Impedance of the Human Ankle With Active Muscles.” ASME 2010 Dynamic Systems and Control Conference, Volume 1 (2010).
Version
Final published version
Abstract
This article compares stochastic estimates of multi-variable human ankle mechanical impedance when ankle muscles were fully relaxed, actively generating ankle torque or co-contracting antagonistically. We employed Anklebot, a rehabilitation robot for the ankle, to provide torque perturbations. Muscle activation levels were monitored electromyographically and these EMG signals were displayed to subjects who attempted to maintain them constant. Time histories of ankle torques and angles in the Dorsi-Plantar flexion (DP) and Inversion-Eversion (IE) directions were recorded. Linear time-invariant transfer functions between the measured torques and angles were estimated for the Anklebot alone and when it was worn by a human subject, the difference between these functions providing an estimate of ankle mechanical impedance. High coherence was observed over a frequency range up to 30 Hz. The main effect of muscle activation was to increase the magnitude of ankle mechanical impedance in both DP and IE directions.
MIT Department
Massachusetts Institute of Technology. Department of Brain and Cognitive Sciences
Massachusetts Institute of Technology. Department of Mechanical Engineering
Terms of Use
Article is made available in accordance with the publisher's policy and may be subject to US copyright law. Please refer to the publisher's site for terms of use.
Persistent DSpace Link
http://hdl.handle.net/1721.1/119384
DOI of Published Version
https://doi.org/10.1115/DSCC2010-4224
Repository logo
PrivacyPermissionsAccessibilityContact us
Repository logo
Notify us about copyright concerns.