Microbubble cell actuator
Name
153265772-MIT.pdf
Description
Full printable version
Size
22.54 MB
Format
Adobe PDF
Checksum (MD5)
c7e4b7670c9afe8e7c63ae53f44fc1ca
Author(s)
Braff, Rebecca A. (Rebecca Alice)
Advisor(s)
Mehmet Toner and Martha Gray.
Date Issued
1999
Publisher
Massachusetts Institute of Technology
Abstract
The field of microsystems technology is rapidly growing, and expanding its horizons to applications in bioengineering. Currently, there are no cell analysis systems that facilitate the collection of dynamic responses for a large number of cells, and sorting based on those results. A cell chip has been fabricated in pursuit of this goal, which can capture particles in an array, hold them against a flow, and selectively release them. The release mechanism uses a vapor microbubble as a means of volume expansion to create a jet of fluid that ejects a particle. The theory, design, and testing are described, and successful operation of the device is demonstrated. Applications and suggestions for future work are discussed.
Description
Thesis (S.M.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 1999.