Repository logo
Log in(current)
Repository logoMIT Open ScholarshipDSpace@MIT
  1. Home
  2. MIT Open Access Articles
  3. MIT Open Access Articles
  4. Measurements of ion cyclotron range of frequencies mode converted wave intensity with phase contrast imaging in Alcator C-Mod and comparison with full-wave simulations

Measurements of ion cyclotron range of frequencies mode converted wave intensity with phase contrast imaging in Alcator C-Mod and comparison with full-wave simulations

Thumbnail Image
Download
Name

porkolab 3.pdf

Size

781.72 KB

Format

Adobe PDF

Checksum (MD5)

9000630e35df2f67f054fa7582c58b82

Author(s)
Jaeger, E. F.
•
Green, D. L.
•
Harvey, R. W.
•
Tsujii, Naoto
•
Porkolab, Miklos
•
Bonoli, Paul T.
•
Lin, Yijun
•
Wright, John C.
•
Wukitch, Stephen James
Date Issued
August 2012
Journal
Physics of Plasmas
Publisher
American Institute of Physics (AIP)
Citation
Tsujii, N., M. Porkolab, P. T. Bonoli, Y. Lin, J. C. Wright, S. J. Wukitch, E. F. Jaeger, D. L. Green, and R. W. Harvey. “Measurements of ion cyclotron range of frequencies mode converted wave intensity with phase contrast imaging in Alcator C-Mod and comparison with full-wave simulations.” Physics of Plasmas 19, no. 8 (2012): 082508.
Version
Author's final manuscript
Abstract
Radio frequency waves in the ion cyclotron range of frequencies (ICRF) are widely used to heat tokamak plasmas. In ICRF heating schemes involving multiple ion species, the launched fast waves convert to ion cyclotron waves or ion Bernstein waves at the two-ion hybrid resonances. Mode converted waves are of interest as actuators to optimise plasma performance through current drive and flow drive. In order to describe these processes accurately in a realistic tokamak geometry, numerical simulations are essential, and it is important that these codes be validated against experiment. In this study, the mode converted waves were measured using a phase contrast imaging technique in D-H and D-[superscript 3]He plasmas. The measured mode converted wave intensity in the D-[superscript 3]He mode conversion regime was found to be a factor of ∼ 50 weaker than the full-wave predictions. The discrepancy was reduced in the hydrogen minority heating regime, where mode conversion is weaker.
MIT Department
Massachusetts Institute of Technology. Plasma Science and Fusion Center
Terms of Use
Creative Commons Attribution-Noncommercial-Share Alike 3.0
http://creativecommons.org/licenses/by-nc-sa/3.0/
Persistent DSpace Link
http://hdl.handle.net/1721.1/80840
DOI of Published Version
https://doi.org/10.1063/1.4745613
Repository logo
PrivacyPermissionsAccessibilityContact us
Repository logo
Notify us about copyright concerns.