Repository logo
Log in(current)
Repository logoMIT Open ScholarshipDSpace@MIT
  1. Home
  2. MIT Open Access Articles
  3. MIT Open Access Articles
  4. Wearable Motion-Based Heart Rate at Rest: A Workplace Evaluation

Wearable Motion-Based Heart Rate at Rest: A Workplace Evaluation

Thumbnail Image
Download
Name

b6908109a0900d19326dfa51fbf6434088fa.pdf

Description
Submitted version
Size

1.86 MB

Format

Adobe PDF

Checksum (MD5)

3c97425ead7e2a41b54166916e68ed10

sword-2019-07-24T16:30:46.original.xml (130 B)
Original SWORD entry document
Author(s)
Hernandez Rivera, Javier
•
McDuff, Daniel Jonathan
•
Quigley, Karen
•
Maes, Patricia
•
Picard, Rosalind W.
Date Issued
September 2019
Journal
IEEE Journal of Biomedical and Health Informatics
Publisher
Institute of Electrical and Electronics Engineers (IEEE)
Citation
Hernandez, Javier et al. "Wearable Motion-Based Heart Rate at Rest: A Workplace Evaluation." IEEE Journal of Biomedical and Health Informatics 23, 5 (September 2019): 1920 - 1927 © 2019 IEEE
Version
Original manuscript
Abstract
IEEE This work studies the feasibility of using low-cost motion sensors to provide opportunistic heart rate assessments from ballistocardiographic signals during restful periods of daily life. Three wearable devices were used to capture peripheral motions at specific body locations (head, wrist and trouser pocket) of 15 participants during five regular workdays each. Three methods were implemented to extract heart rate from motion data and their performance was compared to those obtained with an FDA-cleared device. With a total of 1358 hours of naturalistic sensor data, our results show that providing accurate heart rate estimations from peripheral motion signals is possible during relatively "still" moments. In our real-life workplace study, the head-mounted device yielded the most frequent assessments (22.98% of the time under 5 beats per minute of error) followed by the smartphone in the pocket (5.02%) and the wrist-worn device (3.48%). Most importantly, accurate assessments were automatically detected by using a custom threshold based on the device jerk. Due to the pervasiveness and low-cost of wearable motion sensors, this work demonstrates the feasibility of providing opportunistic large-scale low-cost samples of resting heart rate.
MIT Department
Massachusetts Institute of Technology. Media Laboratory
Terms of Use
Creative Commons Attribution-Noncommercial-Share Alike
http://creativecommons.org/licenses/by-nc-sa/4.0/
Persistent DSpace Link
https://hdl.handle.net/1721.1/126835
DOI of Published Version
https://doi.org/10.1109/jbhi.2018.2877484
Repository logo
PrivacyPermissionsAccessibilityContact us
Repository logo
Notify us about copyright concerns.