The effects of electronic microscanning on infrared image aliasing and spaial resolution
Name
46987815-MIT.pdf
Description
Full printable version
Size
2.74 MB
Format
Adobe PDF
Checksum (MD5)
8d945254ab57a0ad1b1c6b140e74011c
Author(s)
Wexler, Howard Jay
Advisor(s)
William Clem Karl and Thomas R. Briere.
Date Issued
1995
Publisher
Massachusetts Institute of Technology
Abstract
Most modern infrared electro-optical imaging systems utilize staring imagers to acquire image data. Typical staring focal plane arrays contain a two-dimensional array of photodetectors. Each photodetector generates an electrical current or charge proportional to the number of photons striking its immediate vicinity. However, due to the discrete finite nature of the FPA detector lattice and fact that each photodetector's collection area is matched to the optical blur for signal to noise considerations, the imager does not satisfy the Nyquist criteria for sampling systems. Consequently, aliasing effects are usually an inherent part of images produced by staring arrays. Microscanning is a method which can be used to reduce spatial frequency aliasing within an image by spatially oversampling the image scene. During the microscanning process, several optically dithered subimages are acquired and combined to create a larger image. The resulting image will have a higher sampling rate, and accordingly a greater Nyquist cutoff frequency, with the same spatial frequency resolution and optical cutoff frequency. This thesis discusses the effects of a novel approach to the microscanning operation, called electronic microscanning. The electronic microscanning device performs the microscan operation by shifting the collection area of each pixel in the array by half-pixel increments instead of utilizing mechanical or liquid crystal filters to deflect the image. Electronic microscanning has an inherent advantage over traditional microscanning systems since no scanners or moving parts are needed to oversample the image. A model of the electronic microscan device is developed and compared to prototype laboratory results obtained at the Raytheon Company Electro-Optics Laboratory in Tewksbury, Massachusetts.
Description
Thesis (M.S.)--Massachusetts Institute of Technology, Dept. of Electrical Engineering and Computer Science, 1995.
Vita.
Includes bibliographical references (p. 43-44).
Subjects
Electrical Engineering and Computer Science.
MIT Department
Massachusetts Institute of Technology. Department of Electrical Engineering and Computer Science
Terms of Use
M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.
Persistent DSpace Link