  4. Experimental study of an asymmetric valveless pump to elucidate insights into strategies for pediatric extravascular flow augmentation

Experimental study of an asymmetric valveless pump to elucidate insights into strategies for pediatric extravascular flow augmentation

Thumbnail Image
Download
Name

s41598-022-26524-0.pdf

Size

1.76 MB

Format

Adobe PDF

Checksum (MD5)

c3f6c791f780ed933058d720776d9811

sword-2024-04-10T16:31:05.original.xml (130 B)
Original SWORD entry document
Author(s)
Anatol, J.
•
García-Díaz, M.
•
Barrios-Collado, C.
•
Moneo-Fernández, J. A.
•
Horvath, M.
•
Parra, T.
•
Castro-Ruiz, F.
•
Roche, E. T.
•
Sierra-Pallares, J.
Date Issued
December 22, 2022
Journal
Scientific Reports
Publisher
Springer Science and Business Media LLC
Citation
Anatol, J., García-Díaz, M., Barrios-Collado, C. et al. Experimental study of an asymmetric valveless pump to elucidate insights into strategies for pediatric extravascular flow augmentation. Sci Rep 12, 22165 (2022).
Version
Final published version
Abstract
Asymmetric pumping is a sub-category of valveless pumping in which a flexible tube is rhythmically compressed in the transverse symmetry plane. Due to the resulting asymmetry between the suction and discharge pipes, a net pumping head is achieved. Asymmetric pumping is regarded as one of the main mechanisms responsible for the Liebau effect in addition to impedance pumping. However, there remains a paucity of research surrounding the governing parameters of asymmetric pumping. Here, we conducted an experimental study of the performance of an asymmetric pump, with an aim to assess its potential for extravascular flow augmentation. A custom flexible latex tube and experimental platform were developed for this purpose. We tested various tube thicknesses and pinching frequencies. Our results demonstrate that the performance is within the range of physiological requirements for pediatric circulatory devices (~ 1 L/min and < 30 mmHg). We conclude that due to the absence of reverse flow and its mechanical simplicity, pure asymmetric pumping is promising for selected cardiovascular applications with less complexity than other valveless techniques.
Subjects
Multidisciplinary
MIT Department
Massachusetts Institute of Technology. Institute for Medical Engineering & Science
Massachusetts Institute of Technology. Department of Mechanical Engineering
Terms of Use
Creative Commons Attribution
https://creativecommons.org/licenses/by/4.0/
Persistent DSpace Link
https://hdl.handle.net/1721.1/154108
DOI of Published Version
https://doi.org/10.1038/s41598-022-26524-0
Repository logo
PrivacyPermissionsAccessibilityContact us
Repository logo
Notify us about copyright concerns.