High speed, long range, deep penetration swept source OCT for structural and angiographic imaging of the anterior eye
Name
s41598-022-04784-0.pdf
Description
Published version
Size
5.81 MB
Format
Adobe PDF
Checksum (MD5)
be4db66bdb2b6453f2cc91cac411ffdc
Author(s) • • • • • • • •
Chen, Siyu
Potsaid, Benjamin
Li, Yan
Lin, Junhong
Hwang, Yunchan
Moult, Eric M
Zhang, Jason
Huang, David
Fujimoto, James G
Date Issued
2022
Journal
Scientific Reports
Publisher
Springer Science and Business Media LLC
Citation
Chen, Siyu, Potsaid, Benjamin, Li, Yan, Lin, Junhong, Hwang, Yunchan et al. 2022. "High speed, long range, deep penetration swept source OCT for structural and angiographic imaging of the anterior eye." Scientific Reports, 12 (1).
Version
Final published version
Abstract
AbstractThis study reports the development of prototype swept-source optical coherence tomography (SS-OCT) technology for imaging the anterior eye. Advances in vertical-cavity surface-emitting laser (VCSEL) light sources, signal processing, optics and mechanical designs, enable a unique combination of high speed, long range, and deep penetration that addresses the challenges of anterior eye imaging. We demonstrate SS-OCT with a 325 kHz A-scan rate, 12.2 µm axial resolution (in air), and 15.5 mm depth range (in air) at 1310 nm wavelength. The ultrahigh 325 kHz A-scan rate not only facilitates biometry measurements by minimizing acquisition time and thus reducing motion, but also enables volumetric OCT for comprehensive structural analysis and OCT angiography (OCTA) for visualizing vasculature. The 15.5 mm (~ 11.6 mm in tissue) depth range spans all optical surfaces from the anterior cornea to the posterior lens capsule. The 1310 nm wavelength range enables structural OCT and OCTA deep in the sclera and through the iris. Achieving high speed and long range requires linearizing the VCSEL wavenumber sweep to efficiently utilize analog-to-digital conversion bandwidth. Dual channel recording of the OCT and calibration interferometer fringe signals, as well as sweep to sweep wavenumber compensation, is used to achieve invariant 12.2 µm (~ 9.1 µm in tissue) axial resolution and optimum point spread function throughout the depth range. Dynamic focusing using a tunable liquid lens extends the effective depth of field while preserving the lateral resolution. Improved optical and mechanical design, including parallax “split view” iris cameras and stable, ergonomic patient interface, facilitates accurate instrument positioning, reduces patient motion, and leads to improved imaging data yield and measurement accuracy. We present structural and angiographic OCT images of the anterior eye, demonstrating the unique imaging capabilities using representative scanning protocols which may be relevant to future research and clinical applications.
MIT Department
Massachusetts Institute of Technology. Department of Electrical Engineering and Computer Science
Massachusetts Institute of Technology. Research Laboratory of Electronics
Harvard University--MIT Division of Health Sciences and Technology
Terms of Use
Creative Commons Attribution 4.0 International license
Persistent DSpace Link
DOI of Published Version
https://doi.org/10.1038/S41598-022-04784-0