Mechanical vapor compressio--Membrane distillation hybrids for reduced specific energy consumption
Name
MVC-MD-hybrids-DSPACE.pdf
Size
861.06 KB
Format
Adobe PDF
Checksum (MD5)
d71a489bb68f49e9364ad85ad80e3967
Author(s) • •
Swaminathan, Jaichander
Nayar, Kishor Govind
Lienhard, John H
Date Issued
April 2016
Journal
Desalination and Water Treatment
Publisher
Taylor & Francis
Citation
Swaminathan, Jaichander, Kishor G. Nayar, and John H. Lienhard V. “Mechanical Vapor compressio--Membrane Distillation Hybrids for Reduced Specific Energy Consumption.” Desalination and Water Treatment 57, no. 55 (April 28, 2016): 26507-26517.
Version
Author's final manuscript
Abstract
The energy efficiency of membrane distillation (MD) systems is low when compared to other thermal desalination systems. This leads to high water production costs when conventional fuels such as natural gas are used. In MD, separation of pure product water from feedwater is driven by differences in vapor pressure between the streams. Thus, the process can occur at low temperature and ambient pressure. As a result, MD is most frequently paired with waste or renewable sources of low temperature heat energy that can be economically more feasible. MD systems with internal heat regeneration have been compared to and modeled similar to counter-flow heat exchangers. In this study, MD is used to replace the preheater heat exchanger used for thermal energy recovery from the brine stream in mechanical vapor compression (MVC). Using MD in place of the heat exchanger results not only in effectively free thermal energy for MD, but also subsidized cost of capital, since the MD module is replacing expensive heat exchanger equipment. The MVC–MD hybrid system can lead to about 6% decrease in cost of water, compared to a stand-alone MVC system. The savings increase with: an increase in MVC operating temperature, a decrease in MVC recovery ratio, and with a decrease in MD capital cost. The conductive gap configuration of MD leads to maximum savings, followed by air gap and permeate gap systems, over a range of operating conditions, assuming equal specific cost of capital for these configurations.
MIT Department
Massachusetts Institute of Technology. Department of Mechanical Engineering
Rohsenow Kendall Heat Transfer Laboratory (Massachusetts Institute of Technology)
Terms of Use
Creative Commons Attribution-Noncommercial-Share Alike
Persistent DSpace Link
DOI of Published Version
https://doi.org/10.1080/19443994.2016.1168579