Experimental demonstration of an isotope-sensitive warhead verification technique using nuclear resonance fluorescence
Name
4363.full.pdf
Size
898.04 KB
Format
Adobe PDF
Checksum (MD5)
04e81b461d953ea5607a6d3acaee6b5a
Author(s) • •
Vavrek, Jayson Robert
Henderson, Brian Scott
Danagoulian, Areg
Date Issued
April 2018
Journal
Proceedings of the National Academy of Sciences
Publisher
Proceedings of the National Academy of Sciences
Citation
Vavrek, Jayson R., Brian S. Henderson, and Areg Danagoulian. “Experimental Demonstration of an Isotope-Sensitive Warhead Verification Technique Using Nuclear Resonance Fluorescence.” Proceedings of the National Academy of Sciences 115, no. 17 (April 10, 2018): 4363–4368.
Version
Final published version
Abstract
Future nuclear arms reduction efforts will require technologies to verify that warheads slated for dismantlement are authentic without revealing any sensitive weapons design information to international inspectors. Despite several decades of research, no technology has met these requirements simultaneously. Recent work by Kemp et al. [Kemp RS, Danagoulian A, Macdonald RR, Vavrek JR (2016) Proc Natl Acad Sci USA 113:8618–8623] has produced a novel physical cryptographic verification protocol that approaches this treaty verification problem by exploiting the isotope-specific nature of nuclear resonance fluorescence (NRF) measurements to verify the authenticity of a warhead. To protect sensitive information, the NRF signal from the warhead is convolved with that of an encryption foil that contains key warhead isotopes in amounts unknown to the inspector. The convolved spectrum from a candidate warhead is statistically compared against that from an authenticated template warhead to determine whether the candidate itself is authentic. Here we report on recent proof-of-concept warhead verification experiments conducted at the Massachusetts Institute of Technology. Using high-purity germanium (HPGe) detectors, we measured NRF spectra from the interrogation of proxy “genuine” and “hoax” objects by a 2.52 MeV endpoint bremsstrahlung beam. The observed differences in NRF intensities near 2.2 MeV indicate that the physical cryptographic protocol can distinguish between proxy genuine and hoax objects with high confidence in realistic measurement times.
MIT Department
Massachusetts Institute of Technology. Department of Nuclear Science and Engineering
Massachusetts Institute of Technology. Department of Physics
Terms of Use
Article is made available in accordance with the publisher's policy and may be subject to US copyright law. Please refer to the publisher's site for terms of use.
Persistent DSpace Link
DOI of Published Version
https://doi.org/10.1073/PNAS.1721278115