Repository logo
Log in(current)
Repository logoMIT Open ScholarshipDSpace@MIT
  1. Home
  2. MIT Open Access Articles
  3. MIT Open Access Articles
  4. The Impact of Blood Rheology on Drug Transport in Stented Arteries: Steady Simulations

The Impact of Blood Rheology on Drug Transport in Stented Arteries: Steady Simulations

Thumbnail Image
Download
Name

Vijayaratnam-2015-The Impact of Blood.pdf

Size

2.9 MB

Format

Adobe PDF

Checksum (MD5)

d95bebf5a3f3d9ac1b2deaa403f7cd00

Author(s)
Vijayaratnam, Pujith R. S.
•
O’Brien, Caroline C.
•
Reizes, John A.
•
Barber, Tracie J.
•
Edelman, Elazer R.
Date Issued
June 2015
Journal
PLOS ONE
Publisher
Public Library of Science
Citation
Vijayaratnam, Pujith R. S., Caroline C. O’Brien, John A. Reizes, Tracie J. Barber, and Elazer R. Edelman. “The Impact of Blood Rheology on Drug Transport in Stented Arteries: Steady Simulations.” Edited by Victor M Ugaz. PLoS ONE 10, no. 6 (June 12, 2015): e0128178.
Version
Final published version
Abstract
Background and Methods It is important to ensure that blood flow is modelled accurately in numerical studies of arteries featuring drug-eluting stents due to the significant proportion of drug transport from the stent into the arterial wall which is flow-mediated. Modelling blood is complicated, however, by variations in blood rheological behaviour between individuals, blood’s complex near-wall behaviour, and the large number of rheological models which have been proposed. In this study, a series of steady-state computational fluid dynamics analyses were performed in which the traditional Newtonian model was compared against a range of non-Newtonian models. The impact of these rheological models was elucidated through comparisons of haemodynamic flow details and drug transport behaviour at various blood flow rates. Results Recirculation lengths were found to reduce by as much as 24% with the inclusion of a non-Newtonian rheological model. Another model possessing the viscosity and density of blood plasma was also implemented to account for near-wall red blood cell losses and yielded recirculation length increases of up to 59%. However, the deviation from the average drug concentration in the tissue obtained with the Newtonian model was observed to be less than 5% in all cases except one. Despite the small sensitivity to the effects of viscosity variations, the spatial distribution of drug matter in the tissue was found to be significantly affected by rheological model selection. Conclusions/Significance These results may be used to guide blood rheological model selection in future numerical studies. The clinical significance of these results is that they convey that the magnitude of drug uptake in stent-based drug delivery is relatively insensitive to individual variations in blood rheology. Furthermore, the finding that flow separation regions formed downstream of the stent struts diminish drug uptake may be of interest to device designers.
MIT Department
Institute for Medical Engineering and Science
Harvard University--MIT Division of Health Sciences and Technology
Massachusetts Institute of Technology. Center for Biomedical Engineering
Terms of Use
Creative Commons Attribution
http://creativecommons.org/licenses/by/4.0/
Persistent DSpace Link
http://hdl.handle.net/1721.1/98172
DOI of Published Version
https://doi.org/10.1371/journal.pone.0128178
Repository logo
PrivacyPermissionsAccessibilityContact us
Repository logo
Notify us about copyright concerns.