Repository logo
Log in(current)
Repository logoMIT Open ScholarshipDSpace@MIT
  1. Home
  2. MIT Open Access Articles
  3. MIT Open Access Articles
  4. Study of Bioengineered Zebra Fish Olfactory Receptor 131-2: Receptor Purification and Secondary Structure Analysis

Study of Bioengineered Zebra Fish Olfactory Receptor 131-2: Receptor Purification and Secondary Structure Analysis

Thumbnail Image
Download
Name

Lecj-2010-Study of Bioengineered Zebra Fish Olfactory Receptor 131-2 Receptor Purification and Secondary Structure Analysis.pdf

Size

330.07 KB

Format

Adobe PDF

Checksum (MD5)

6bca24cd63da43b0009fb7195b4d783d

Author(s)
Leck, Kwong-Joo
•
Zhang, Shuguang
•
Hauser, Charlotte A. E.
Date Issued
November 2010
Journal
PLoS ONE
Publisher
Public Library of Science
Citation
Leck, Kwong-Joo, Shuguang Zhang, and Charlotte A. E. Hauser. “Study of Bioengineered Zebra Fish Olfactory Receptor 131-2: Receptor Purification and Secondary Structure Analysis.” PLoS ONE 5.11 (2010) : e15027.
Version
Final published version
Abstract
How fishes are able to detect trace molecules in large bodies of water is not understood. It is plausible that they use olfactory receptors to detect water-soluble compounds. How the zebra fish Danio Rerio, an organism with only 98 functional olfactory receptors, is able to selectively detect and recognize numerous compounds in water remains a puzzling phenomenon. We are interested in studying the biochemical and molecular mechanisms of olfaction in fish. Here, we report on the study of a bioengineered zebra fish olfactory receptor OR131-2, affinity-purified from a HEK293S tetracycline-inducible system. This receptor was expressed and translocated to the cell plasma membrane as revealed by confocal microscopy. Circular dichroism spectroscopy showed that the purified zebra fish receptor folded into an α-helical structure, as observed for other G-protein coupled receptors (GPCRs). Our study shows that it is possible to produce viable quantities of the zebra fish olfactory receptor. This will not only enable detailed structural and functional analyses, but also aid in the design of biosensor devices in order to detect water-soluble metabolites or its intermediates, which are associated with human health.
MIT Department
Massachusetts Institute of Technology. Center for Biomedical Engineering
Terms of Use
Creative Commons Attribution
http://creativecommons.org/licenses/by/2.5/
Persistent DSpace Link
http://hdl.handle.net/1721.1/64458
DOI of Published Version
https://doi.org/10.1371/journal.pone.0015027
Repository logo
PrivacyPermissionsAccessibilityContact us
Repository logo
Notify us about copyright concerns.