Show simple item record

dc.contributor.advisorAmos G. Winter, V.en_US
dc.contributor.authorArelekatti, Venkata Narayana Murthyen_US
dc.contributor.otherMassachusetts Institute of Technology. Department of Mechanical Engineering.en_US
dc.coverage.spatiala-ii---en_US
dc.date.accessioned2015-12-03T20:56:59Z
dc.date.available2015-12-03T20:56:59Z
dc.date.copyright2015en_US
dc.date.issued2015en_US
dc.identifier.urihttp://hdl.handle.net/1721.1/100156
dc.descriptionThesis: S.M., Massachusetts Institute of Technology, Department of Mechanical Engineering, 2015.en_US
dc.descriptionCataloged from PDF version of thesis.en_US
dc.descriptionIncludes bibliographical references (pages 51-54).en_US
dc.description.abstractAn estimated 230,000 above-knee amputees are in need of prosthetic devices in India with a majority of them facing severe socio-economic constraints in their daily lives. However, only a few passive prosthetic knee devices in the market have been designed to enable normative gait and to meet the unique daily life needs of above-knee amputees in the developing world. This thesis builds upon a past study at MIT, which established optimal mechanical component coefficients in prosthetic knee function required for achieving able-bodied kinematics. A mechanism for the design of a fully passive, low-cost prosthetic knee device, which aims to facilitate able-bodied kinematics at a low metabolic cost is presented. The mechanism is implemented using an automatic early stance lock for stability, a linear spring for early stance flexionextension and a differential friction damping system for late stance and swing control. For preliminary validation of the knee mechanism two field trials were carried out on five above-knee amputees in India, which showed satisfactory performance of the early stance lock and enabled smooth stance to swing transition by timely initiation of late stance flexion.en_US
dc.description.statementofresponsibilityby Venkata Narayana Murthy, Arelekatti.en_US
dc.format.extent54 pagesen_US
dc.language.isoengen_US
dc.publisherMassachusetts Institute of Technologyen_US
dc.rightsM.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.en_US
dc.rights.urihttp://dspace.mit.edu/handle/1721.1/7582en_US
dc.subjectMechanical Engineering.en_US
dc.titleDesign of low-cost, fully passive prosthetic knee for persons with transfemoral amputation in Indiaen_US
dc.typeThesisen_US
dc.description.degreeS.M.en_US
dc.contributor.departmentMassachusetts Institute of Technology. Department of Mechanical Engineering
dc.identifier.oclc930153026en_US