MIT Libraries logoDSpace@MIT

MIT
View Item 
  • DSpace@MIT Home
  • MIT Libraries
  • MIT Theses
  • Graduate Theses
  • View Item
  • DSpace@MIT Home
  • MIT Libraries
  • MIT Theses
  • Graduate Theses
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.

Improved accuracy in susceptibility-based OEF measurements by mitigation of partial-volume effects via combined magnitude and phase reconstruction

Author(s)
McDaniel, Patrick Christopher
Thumbnail
DownloadFull printable version (4.246Mb)
Alternative title
Improved accuracy in susceptibility-based MRI oxygenation measurements by mitigation of partial-volume effects via combined magnitude and phase reconstruction
Other Contributors
Massachusetts Institute of Technology. Department of Electrical Engineering and Computer Science.
Advisor
Elfar Adalsteinsson.
Terms of use
M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission. http://dspace.mit.edu/handle/1721.1/7582
Metadata
Show full item record
Abstract
Regional quantitative Oxygen Extraction Fraction (OEF) values can only be reliable obtained from blood vessels larger than the acquisition voxel size. Blood vessels beyond this limit produce unreliable measurements due to partial-volume effects. We demonstrate a method for obtaining more reliable OEF measurements beyond this limit by performing a joint reconstruction using both the magnitude and phase of the complex-valued MRI signal. This method is validated both in numerical simulations and on in vivo data. The ability to perform high-quality fetal brain imaging is hampered by motion of the fetus, which can severely degrade image quality. Previously, low-resolution volumetric navigator (vNav) acquisitions have been shown to accurately track motion in human adults and prospectively correct for it. Here, a technique for using vNavs to measure fetal head motion in utero is developed and validated on in vivo data. Parallel Transmission (pTx) improves image quality and patient safety in high-field MRI. Unlike in single-channel MR excitation, an array of multiple excitation coils is used in pTx. However, coupling between these independent coils significantly degrades the power efficiency of the pTx array. Previously, it a decoupling matrix was proposed to solve this inefficiency. In this work, a physical realization of a 4-channel decoupling matrix was constructed and tested.
Description
Thesis: M. Eng., Massachusetts Institute of Technology, Department of Electrical Engineering and Computer Science, 2015.
 
This electronic version was submitted by the student author. The certified thesis is available in the Institute Archives and Special Collections.
 
Title as it appears in MIT Commencement Exercises program, June 5, 2015: Improved accuracy in susceptibility-based MRI oxygenation measurements by mitigation of partial-volume effects via combined magnitude and phase reconstruction. Cataloged from student-submitted PDF version of thesis.
 
Includes bibliographical references.
 
Date issued
2015
URI
http://hdl.handle.net/1721.1/100637
Department
Massachusetts Institute of Technology. Department of Electrical Engineering and Computer Science
Publisher
Massachusetts Institute of Technology
Keywords
Electrical Engineering and Computer Science.

Collections
  • Graduate Theses

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

My Account

Login

Statistics

OA StatisticsStatistics by CountryStatistics by Department
MIT Libraries
PrivacyPermissionsAccessibilityContact us
MIT
Content created by the MIT Libraries, CC BY-NC unless otherwise noted. Notify us about copyright concerns.