Show simple item record

dc.contributor.advisorJoel Voldman.en_US
dc.contributor.authorDighe, Aalap (Aalap Shirish)en_US
dc.contributor.otherMassachusetts Institute of Technology. Department of Mechanical Engineering.en_US
dc.date.accessioned2016-03-03T21:07:04Z
dc.date.available2016-03-03T21:07:04Z
dc.date.copyright2015en_US
dc.date.issued2015en_US
dc.identifier.urihttp://hdl.handle.net/1721.1/101531
dc.descriptionThesis: Ph. D., Massachusetts Institute of Technology, Department of Mechanical Engineering, 2015.en_US
dc.descriptionCataloged from PDF version of thesis.en_US
dc.descriptionIncludes bibliographical references (pages 175-181).en_US
dc.description.abstractElectrical interfaces with the nervous system are critical for enabling neurally-controlled prostheses and for creating better therapies for neurological disorders. Microelectrodes that penetrate into brain tissue to record extracellular electrical activity are one such neural interface technology known for their unparalleled spatial and temporal signal resolution. However, a major challenge with reliable chronic recording with such interfaces is tissue reaction, wherein a sheath of glial cells encapsulates the neural probe, electrically insulating the probe from the surrounding neurons. This work presents the design, fabrication, and characterization of a thin polymer probe whose body can be deflected and locked prior to insertion via a glue, storing mechanical energy in the device. After inserting into the brain and waiting for the initial glial sheath to form, the device can be deployed by melting the glue, causing the recording tip of the device to penetrate into fresh tissue. It is hypothesized that small tip dimensions (10-20 [mu]m) should prevent the formation of an additional glial sheath post-deployment and thus enable chronic recording. Four successive generations of devices were fabricated, characterized in benchtop tests, and subsequently tested in the rat model and in the optogenetic Thyl-ChR2-YFP mouse model. The electrical and mechanical functionality of the probe was confirmed under acute in vivo conditions in the medial prefrontal cortex of optogenetic Thyl-ChR2-YFP mice. Neural activity was successfully recorded from the probe immediately after insertion using laser stimulation of the mouse brain. Applying saline to the water-soluble glue caused the probe to deploy and neural activity was successfully recorded post-deployment. These results demonstrate the first in vivo deployment and electrical recordings from a reconfigurable neural probe with small dimensions (< 20 [mu]m) and hold promise for the creation of chronic recording neural interfaces.en_US
dc.description.statementofresponsibilityby Aalap Dighe.en_US
dc.format.extent181 pagesen_US
dc.language.isoengen_US
dc.publisherMassachusetts Institute of Technologyen_US
dc.rightsM.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.en_US
dc.rights.urihttp://dspace.mit.edu/handle/1721.1/7582en_US
dc.subjectMechanical Engineering.en_US
dc.titleReconfigurable neural probes for chronic electrical recordingen_US
dc.typeThesisen_US
dc.description.degreePh. D.en_US
dc.contributor.departmentMassachusetts Institute of Technology. Department of Mechanical Engineering
dc.identifier.oclc939919720en_US


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record