Show simple item record

dc.contributor.advisorKlavs F. Jensen.en_US
dc.contributor.authorShatova, Tatyana Aen_US
dc.contributor.otherMassachusetts Institute of Technology. Department of Chemical Engineering.en_US
dc.date.accessioned2016-08-02T20:08:07Z
dc.date.available2016-08-02T20:08:07Z
dc.date.copyright2015en_US
dc.date.issued2015en_US
dc.identifier.urihttp://hdl.handle.net/1721.1/103847
dc.descriptionThesis: Ph. D., Massachusetts Institute of Technology, Department of Chemical Engineering, 2015.en_US
dc.descriptionCataloged from PDF version of thesis.en_US
dc.descriptionIncludes bibliographical references (pages 127-136).en_US
dc.description.abstractPoint of care testing is expanding the healthcare field towards personalized and early-detection medicine. Microfluidic platforms present an opportunity for low cost, portable diagnostic sensors through manipulation of small volumes of fluids on isolated, compact devices. One of the challenges of microfluidic sensors is the biological sample pretreatment steps that are manually performed prior to on-chip loading and sensing. This issue is especially prominent for human blood, which contains about a billion cells in one milliliter total volume. These blood cells can rupture, clog devices, block optical readouts, and foul electrodes. At the same time, the liquid portion of human blood, plasma, is rich in a variety of disease indicators, many of which have not yet been identified, and thus is an essential part in the diagnostic field. This thesis focuses on the design of a small, around 1 cm long, microfluidic device that separates out blood plasma from undiluted human blood. This design does not require any external field or equipment, beyond a loading syringe and collection tubing. The separation results show 10-100 times improvement in plasma purity over the literature values for passive separation designs. This separation system was then combined with a colorimetric malaria sensor that produced a visually detectable colored result with a 7.5 nM limit of detection in whole blood. This thesis details the design of a low power point of care diagnostic process that is capable of blood processing and detection, and which eliminates the need for any external laboratory-scale equipment. Advantages and challenges of other low power, microfluidic sensor constructs are also discussed.en_US
dc.description.statementofresponsibilityby Tatyana A. Shatova.en_US
dc.format.extent136 pagesen_US
dc.language.isoengen_US
dc.publisherMassachusetts Institute of Technologyen_US
dc.rightsM.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.en_US
dc.rights.urihttp://dspace.mit.edu/handle/1721.1/7582en_US
dc.subjectChemical Engineering.en_US
dc.titlePortable blood plasma separation for point of care diagnosticsen_US
dc.typeThesisen_US
dc.description.degreePh. D.en_US
dc.contributor.departmentMassachusetts Institute of Technology. Department of Chemical Engineering
dc.identifier.oclc953873968en_US


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record