Show simple item record

dc.contributor.advisorThomas Roemer and Jung-Hoon Chun.en_US
dc.contributor.authorSchacherl, Jeffrey Den_US
dc.contributor.otherLeaders for Global Operations Program.en_US
dc.date.accessioned2016-09-13T19:23:38Z
dc.date.available2016-09-13T19:23:38Z
dc.date.copyright2016en_US
dc.date.issued2016en_US
dc.identifier.urihttp://hdl.handle.net/1721.1/104305
dc.descriptionThesis: M.B.A., Massachusetts Institute of Technology, Sloan School of Management, 2016. In conjunction with the Leaders for Global Operations Program at MIT.en_US
dc.descriptionThesis: S.M. in Engineering Systems, Massachusetts Institute of Technology, Department of Mechanical Engineering, 2016. In conjunction with the Leaders for Global Operations Program at MIT.en_US
dc.descriptionCataloged from PDF version of thesis.en_US
dc.descriptionIncludes bibliographical references (pages 84-86).en_US
dc.description.abstractBaked-in siliconization of glass cylinders, primary insulin containers, is a manufacturing process that is critical to the performance of drug delivery devices. Delivery devices are evolving and placing additional burden on production processes. Variability in siliconization and baking processes affects the resulting friction characteristics that are related to device performance criteria such as injection time and velocity, which are critical to the patient experience. The principal objective is to better characterize the performance of siliconized and baked glass, enabling improvement of device injection performance. A controlled study was conducted in order to strip away extraneous variables and enhance experimental control. State-of-the-art nanoscale measurement techniques and tribological (friction) equipment were employed to test the physical characteristics of silicone-coated glass. Data collected was statistically analyzed to determine relative significance of primary factors as well as variable interactions, with respect to friction of the rubber versus coated glass system. Lack of silicone or "dry spots" were found to be a key concern for siliconized glass. Siliconization amount was empirically modeled and found to have an exponential relationship with the coefficient of friction. High velocities exacerbated issues arising from lack of silicone. Based on the test results, a clearer definition of proper baked-in glass siliconization has emerged. Recommendations included minimum siliconization amount and an awareness of significant variable effects and interactions on system friction. Groundwork has been laid for further work including process optimization in the pursuit of improving insulin delivery device injection performance. The opinions expressed herein are solely those of the author and do not necessarily reflect those of Sanofi.en_US
dc.description.statementofresponsibilityby Jeffrey D. Schacherl.en_US
dc.format.extent92 pagesen_US
dc.language.isoengen_US
dc.publisherMassachusetts Institute of Technologyen_US
dc.rightsM.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.en_US
dc.rights.urihttp://dspace.mit.edu/handle/1721.1/7582en_US
dc.subjectSloan School of Management.en_US
dc.subjectMechanical Engineering.en_US
dc.subjectLeaders for Global Operations Program.en_US
dc.titleGlass siliconization process characterization for insulin delivery device performanceen_US
dc.typeThesisen_US
dc.description.degreeM.B.A.en_US
dc.description.degreeS.M. in Engineering Systemsen_US
dc.contributor.departmentLeaders for Global Operations Program at MITen_US
dc.contributor.departmentMassachusetts Institute of Technology. Department of Mechanical Engineering
dc.contributor.departmentSloan School of Management
dc.identifier.oclc958277942en_US


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record