Show simple item record

dc.contributor.advisorTimothy M. Swager.en_US
dc.contributor.authorAzzarelli, Joseph M. (Joseph Michael)en_US
dc.contributor.otherMassachusetts Institute of Technology. Department of Chemistry.en_US
dc.date.accessioned2016-09-30T19:36:08Z
dc.date.available2016-09-30T19:36:08Z
dc.date.copyright2016en_US
dc.date.issued2016en_US
dc.identifier.urihttp://hdl.handle.net/1721.1/104569
dc.descriptionThesis: Ph. D., Massachusetts Institute of Technology, Department of Chemistry, 2016.en_US
dc.descriptionCataloged from PDF version of thesis.en_US
dc.descriptionIncludes bibliographical references.en_US
dc.description.abstractIn Chapter 1, we develop a brief tutorial on chemiresistive sensors and our rationale for choosing nanowires (NWs), specifically carbon nanotubes (CNTs), as the basis for chemiresistor research. Due to their high surface area, interwire junctions, and restricted conduction pathways, NWs give intrinsically high sensitivity and new mechanisms to transduce the binding or action of analytes. We explore principles for understanding electrical transport and transduction mechanisms in NW sensors. Next, we offer the reader a review of chemical sensor device performance parameters. Then, we summarize NW assembly and different device platform architectures. Subsequently, we discuss CNT functionalization strategies. Finally, we propose future developments in NW sensing to address selectivity, sensor drift, sensitivity, response analysis, and emerging applications. In Chapter 2, we describe a rapid, solvent-free, two-step procedure for the fabrication of selective gas and vapor sensors from carbon nanotubes and graphite on the surface of paper that overcomes challenges associated with solvent-assisted chemical functionalization and integration of these materials into devices. The first step generates solid composites from carbon nanotubes (or graphite) and small molecules (chosen to interact with specific types of gases and vapors) by mechanical mixing and subsequent compression into a form similar to a conventional pencil "lead." The second step uses mechanical abrasion ("drawing") of these solid composites on the surface of paper to generate functional devices. The use of diverse composites yields sensing arrays capable of detecting and differentiating gases and vapors at part-per-million concentrations. In Chapter 3, we describe an adaption of near-field communication (NFC) technology toward portable, wireless, non-line-of-sight gas phase chemical sensing. The result is a Chemically Actuated Resonant Device (CARD). We demonstrate the ability to convert inexpensive commercial NFC tags into chemical sensors that detect and discriminate analytes at part-per-thousand and part-per-million concentrations. This effort merges rational design of conductive nanostructured materials for selective chemical sensing with portable and widely distributed NFC technology to deliver a new method of acquiring chemical information about an NFC tag's local environment. We introduce a concept for distributed chemical sensing by the growing number of people that carry NFC-enabled smartphones, tablets, and other smart devices. We highlight second-generation NFC-based chemical sensor circuit designs that generalize turn-on/turn-off functionality. Finally, we devise a new Chemically Actuated Resonant Device (CARD) architecture that simplifies device fabrication to a single step and unambiguously relates change in chemiresistance to a wireless CARD readout. In Chapter 4, we describe a single-use wearable hazard badge that dosimetrically detects diethylchlorophosphate (DCP), a model organophosphorous cholinesterase inhibitor simulant. To provide selective and readily manufacturable sensor elements, we developed an ionic liquid-mediated single walled carbon nanotube based chemidosimetric scheme capable of detecting DCP across a broad dynamic range with limits of detection of 28 parts-per-billion (ppb). Furthermore, we have established a relationship between CARD readout and exposure dose, which can be generalized for any dosimeter developed with this device architecture. The device's practical utility is demonstrated wherein an 8-hour workday time weighted average equivalent exposure of 10 ppb DCP effects an irreversible change in smartphone readout. Finally, we show that the device is selective for DCP by screening against 8 commonly encountered interferent gases and vapors. In Chapter 5, we seek to develop an alkene dosimeter by exploiting known [4+2] cycloaddition chemistries. Specifically, di-substituted- 1,2,4,5-tetrazines are employed as a model inverse-electron demand Diels-Alder agent for the dosimetric detection of ethylene. Possible device architectures and fabrication strategies are explored, including colorimetric and chemiresistive implementations. A new solid/liquid chemiresistor fabrication method is demonstrated, and future directions for improving the sensitivity of diene-type alkene dosimeters are discussed.en_US
dc.description.statementofresponsibilityby Joseph M. Azzarelli.en_US
dc.format.extent198 pagesen_US
dc.language.isoengen_US
dc.publisherMassachusetts Institute of Technologyen_US
dc.rightsM.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.en_US
dc.rights.urihttp://dspace.mit.edu/handle/1721.1/7582en_US
dc.subjectChemistry.en_US
dc.titleWirelessly addressable chemiresistors : carbon nanotube-based chemical sensors and dosimetersen_US
dc.typeThesisen_US
dc.description.degreePh. D.en_US
dc.contributor.departmentMassachusetts Institute of Technology. Department of Chemistry
dc.identifier.oclc958663823en_US


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record