Show simple item record

dc.contributor.advisorMichael J. Cima.en_US
dc.contributor.authorLi, Matthew, Ph. D. Massachusetts Institute of Technologyen_US
dc.contributor.otherHarvard--MIT Program in Health Sciences and Technology.en_US
dc.date.accessioned2016-09-30T19:38:21Z
dc.date.available2016-09-30T19:38:21Z
dc.date.issued2016en_US
dc.identifier.urihttp://hdl.handle.net/1721.1/104612
dc.descriptionThesis: Ph. D. in Medical Engineering and Medical Physics, Harvard-MIT Program in Health Sciences and Technology, 2016.en_US
dc.description"June 2016." Cataloged from PDF version of thesis.en_US
dc.descriptionIncludes bibliographical references (pages 131-154).en_US
dc.description.abstractFluid volume status is a physiologic parameter that currently lacks a reliable diagnostic tool. Volume control becomes an issue during sickness and/or stress (physical and mental) in a wide range of populations. Unfortunately, current diagnostics suffer from being imprecise, invasive, and/or easily confounded and cannot unambiguously and practically inform volume status. There exists a need for a tool that can inform individuals and clinicians of fluid status in a noninvasive, rapid, and reliable manner. Drawing on the molecular sensitivity of IH nuclear magnetic resonance (NMR), we explored the ability of NMR methods to quantitate physiologic fluid volume changes. We first proved that NMR methods could detect volume changes in an animal model of dehydration. Correlation between NMR value changes in specific tissues and clinical tools used to assess dehydration validate NMR as a viable tool. We then proceeded to design and fabricate practical NMR sensors that could be easily integrated into the clinic. New methods of magnetic instrument design optimized for both field strength and spatial resolution were developed resulting in compact device prototypes with signal fidelity rivaling those of impractical commercial systems. Finally, we explored the ability of these devices to detect intravascular fluid changes during hemodialysis. Our methods and devices were able to detect intravascular blood property changes associated with blood dilution, in addition to overall fluid volume changes due to hemodialysis therapy. These results, methods, and devices provide the foundation and framework for the integration of NMR-based personalized fluid volume assessment into standard clinical practice.en_US
dc.description.statementofresponsibilityby Matthew Li.en_US
dc.format.extent154 pagesen_US
dc.language.isoengen_US
dc.publisherMassachusetts Institute of Technologyen_US
dc.rightsM.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.en_US
dc.rights.urihttp://dspace.mit.edu/handle/1721.1/7582en_US
dc.subjectHarvard--MIT Program in Health Sciences and Technology.en_US
dc.titleMethods and devices for noninvasive physiologic fluid volume assessmenten_US
dc.typeThesisen_US
dc.description.degreePh. D. in Medical Engineering and Medical Physicsen_US
dc.contributor.departmentHarvard University--MIT Division of Health Sciences and Technology
dc.identifier.oclc959002246en_US


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record