A wearable Transcranial Doppler ultrasound phased array system

Author(s)
Pietrangelo, Sabino Joseph
Thumbnail
DownloadFull printable version (33.60Mb)
Alternative title
Wearable TCD ultrasound phased array system
Other Contributors
Massachusetts Institute of Technology. Department of Electrical Engineering and Computer Science.
Advisor
Charles G. Sodini and Hae-Seung Lee.
Terms of use
MIT theses are protected by copyright. They may be viewed, downloaded, or printed from this source but further reproduction or distribution in any format is prohibited without written permission. http://dspace.mit.edu/handle/1721.1/7582
Metadata
Show full item record
Abstract
Transcranial Doppler (TCD) sonography is a specialized ultrasound technique that enables measurement of blood ow velocity from the basal intracerebral vessels. Use of TCD sonography is highly compelling as a diagnostic modality due to its safety in prolonged studies, high temporal resolution, and relative portability. Although TCD methods have been clinically indicated in a variety of cerebrovascular diagnostic applications, general acceptance by the medical community has been impeded by several critical deficiencies { including the need for a highly-trained TCD operator, operator dependent measurement results, and severe patient movement restrictions. This thesis seeks to mitigate such limitations through the development of a compact, wearable TCD ultrasound system, permitting untethered cerebrovascular monitoring with limited operator interaction. The prototype system incorporates a custom two-dimensional transducer array and multi-channel transceiver electronics, thereby facilitating acoustic focusing via phased array operation. Algorithmic vessel search and tracking further reduce operator dependencies by expediting vessel localization, systematizing vessel identification, and dynamically adapting to relative vessel position. Additionally, focal correction methods are presented, which improve acoustic beamformation capabilities in the presence of tissue inhomogeneities. Validation of the prototype hardware and embedded signal processing implementations under flow phantom and human subject testing yields high correlation with accepted velocimetry methods. Vessel search and tracking functionality are also verified experimentally. Circuit integration is explored to further reduce instrumentation dimensions and power consumption.
Description
Thesis: Ph. D., Massachusetts Institute of Technology, Department of Electrical Engineering and Computer Science, 2017.
 
This electronic version was submitted by the student author. The certified thesis is available in the Institute Archives and Special Collections.
 
Cataloged from student-submitted PDF version of thesis.
 
Includes bibliographical references (pages 183-190).
 
Date issued
2017
URI
http://hdl.handle.net/1721.1/108848
Department
Massachusetts Institute of Technology. Department of Electrical Engineering and Computer Science
Publisher
Massachusetts Institute of Technology
Keywords
Electrical Engineering and Computer Science.

Collections
  • Doctoral Theses

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

My Account

Login

Statistics

OA StatisticsStatistics by CountryStatistics by Department
MIT Libraries
PrivacyPermissionsAccessibilityContact us
MIT
Content created by the MIT Libraries, CC BY-NC unless otherwise noted. Notify us about copyright concerns.