MIT Libraries logoDSpace@MIT

MIT
View Item 
  • DSpace@MIT Home
  • MIT Libraries
  • MIT Theses
  • Undergraduate Theses
  • View Item
  • DSpace@MIT Home
  • MIT Libraries
  • MIT Theses
  • Undergraduate Theses
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.

Experimental evaluation of polychromatic neutron diffraction

Author(s)
Morrell, Jonathan T
Thumbnail
DownloadFull printable version (747.2Kb)
Other Contributors
Massachusetts Institute of Technology. Department of Nuclear Science and Engineering.
Advisor
David Moncton and Boris Khaykovich.
Terms of use
MIT theses are protected by copyright. They may be viewed, downloaded, or printed from this source but further reproduction or distribution in any format is prohibited without written permission. http://dspace.mit.edu/handle/1721.1/7582
Metadata
Show full item record
Abstract
Neutron diffraction is a technique that allows scientists to measure the arrangement and motions of atoms in a crystalline lattice by observing neutrons scattering at angles that are characteristic of the interatomic distances of the crystal. This is useful for studying the response of crystals to stress, irradiation, or for observing their phases. This thesis implements and analyzes a technique known as polychromatic neutron powder diffraction, which has the potential to be used by an instrument to make many simultaneous neutron diffraction measurements. In this experiment, powder diffraction patterns were measured with a diffractometer in polychromatic mode, using both angle-dispersive and wavelength-dispersive scans of a silicon powder. The intensity and resolution of the Bragg peaks with the instrument in this configuration were compared to Bragg peaks measured by the same instrument in a monochromatic configuration. The intensity of the polychromatic mode was only comparable to the monochromatic mode with looser collimation, which had the consequence of increasing the widths of the measured peaks. This resulted in a polychromatic signal intensity that was greater than the monochromatic signal intensity, and a Bragg peak that was wider than the monochromatic Bragg peak. The effects of the collimators and the sample to detector distances were quantified in experiment and in ray-tracing simulations. While both the monochromatic and the polychromatic configurations had similar counting rates in this experiment, they were both limited by the high background due to the open-beam geometry. A successful implementation of a polychromatic instrument would require substantial filtering and shielding to overcome this effect.
Description
Thesis: S.B., Massachusetts Institute of Technology, Department of Nuclear Science and Engineering, 2017.
 
This electronic version was submitted by the student author. The certified thesis is available in the Institute Archives and Special Collections.
 
Cataloged from student-submitted PDF version of thesis.
 
Includes bibliographical references (pages 57-58).
 
Date issued
2017
URI
http://hdl.handle.net/1721.1/112368
Department
Massachusetts Institute of Technology. Department of Nuclear Science and Engineering
Publisher
Massachusetts Institute of Technology
Keywords
Nuclear Science and Engineering.

Collections
  • Undergraduate Theses

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

My Account

Login

Statistics

OA StatisticsStatistics by CountryStatistics by Department
MIT Libraries
PrivacyPermissionsAccessibilityContact us
MIT
Content created by the MIT Libraries, CC BY-NC unless otherwise noted. Notify us about copyright concerns.