MIT Libraries logoDSpace@MIT

MIT
View Item 
  • DSpace@MIT Home
  • MIT Libraries
  • MIT Theses
  • Undergraduate Theses
  • View Item
  • DSpace@MIT Home
  • MIT Libraries
  • MIT Theses
  • Undergraduate Theses
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.

Causes and analysis of failures in in-situ microscopy observation for the characterization of scaling in membrane distillation membranes

Author(s)
Polanco, Pedro (Pedro D.)
Thumbnail
DownloadFull printable version (3.311Mb)
Other Contributors
Massachusetts Institute of Technology. Department of Mechanical Engineering.
Advisor
John H. Lienhard, V.
Terms of use
MIT theses are protected by copyright. They may be viewed, downloaded, or printed from this source but further reproduction or distribution in any format is prohibited without written permission. http://dspace.mit.edu/handle/1721.1/7582
Metadata
Show full item record
Abstract
In membrane technology at large, fouling limits membrane performance and membrane lifespan. In the case of reverse osmosis membrane distillation (MD) involving fluid mixtures of inorganic elements, inorganic foulants build up on membrane surfaces, and reduce the flux of fluids across a membrane. Inorganic fouling can degrade the quality of water produced by membrane distillation. In order to counteract the effects of membrane fouling, potentially costly procedures like intense chemical cleaning or membrane replacement are necessary. Some theory suggests that, instead of reacting and adhering to membrane surfaces, salts tend to bulk nucleate in solution, and then deposit on high energy surfaces, like metal heat exchangers and hydrophilic reverse osmosis membranes. This is in contrast to the theory that crystals first deposit on the membrane surface to cause fouling. A solution of Na2SO4. and CaCl, was pumped across a membrane at 70°C at 2.6 GPM (9.8 LPM) to observe membrane fouling. Using an in-situ camera, fouling on a membrane distillation surface was captured to characterize the nature of MD fouling. Due to failures in heat distribution across the solution and system leaking, no fouling on the membrane surface was observed.
Description
Thesis: S.B., Massachusetts Institute of Technology, Department of Mechanical Engineering, 2017.
 
Cataloged from PDF version of thesis.
 
Includes bibliographical references (page 27).
 
Date issued
2017
URI
http://hdl.handle.net/1721.1/112549
Department
Massachusetts Institute of Technology. Department of Mechanical Engineering
Publisher
Massachusetts Institute of Technology
Keywords
Mechanical Engineering.

Collections
  • Undergraduate Theses

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

My Account

Login

Statistics

OA StatisticsStatistics by CountryStatistics by Department
MIT Libraries
PrivacyPermissionsAccessibilityContact us
MIT
Content created by the MIT Libraries, CC BY-NC unless otherwise noted. Notify us about copyright concerns.