Show simple item record

dc.contributor.advisorDaniel Frey.en_US
dc.contributor.authorMiller, Sally Aen_US
dc.contributor.otherMassachusetts Institute of Technology. Department of Mechanical Engineering.en_US
dc.date.accessioned2018-05-23T16:28:46Z
dc.date.available2018-05-23T16:28:46Z
dc.date.copyright2018en_US
dc.date.issued2018en_US
dc.identifier.urihttp://hdl.handle.net/1721.1/115652
dc.descriptionThesis: S.M., Massachusetts Institute of Technology, Department of Mechanical Engineering, 2018.en_US
dc.descriptionCataloged from PDF version of thesis.en_US
dc.descriptionIncludes bibliographical references (pages 59-60).en_US
dc.description.abstractAccess to surgical care for people in remote settings and/or developing countries is limited: 30% of the world's population receives 75% of major operations [1]. In developing countries, up to a third of patients acquire a surgical site infection (SSI), which is nine times more likely than in developed countries [2]. An estimated 85,500 cases of HIV and hepatitis are contracted by obstetrical/gynecological providers every year, and 90% of those cases are the result of treating patients living in poverty. SurgiBox aims to address these issues by providing a portable, sterile operating environment for use in austere settings. Not only are patients protected from environmental hazards through the use of SurgiBox, but medical personnel are also shielded from patient fluids, blood, and aerosols. SurgiBox consists of a clear, disposable plastic enclosure that is adhered to the patient's surgical site and inflated with filtered air. Long gloves, similar those used in a glovebox, are integrated into the enclosure and used by the medical personnel to perform the surgery. Surgical instruments are sterilized before the surgery and are placed inside the enclosure prior to the procedure, but materials, or even a baby in the case of a cesarean section, can be passed in or out of the sterile field during the procedure through a resealable port. Particle count testing inside the enclosure shows that particle counts could be maintained at less than 25% of operating room standards for particles greater than 0.5 microns (OR standard: less than 83,000 particles/m3)and 0.3 microns (OR standard: less than 1,000,000 particles/m 3 ).en_US
dc.description.statementofresponsibilityby Sally A. Miller.en_US
dc.format.extent63 pagesen_US
dc.language.isoengen_US
dc.publisherMassachusetts Institute of Technologyen_US
dc.rightsMIT theses are protected by copyright. They may be viewed, downloaded, or printed from this source but further reproduction or distribution in any format is prohibited without written permission.en_US
dc.rights.urihttp://dspace.mit.edu/handle/1721.1/7582en_US
dc.subjectMechanical Engineering.en_US
dc.titleDesign of an ultraportable surgical enclosure for low resource environmentsen_US
dc.typeThesisen_US
dc.description.degreeS.M.en_US
dc.contributor.departmentMassachusetts Institute of Technology. Department of Mechanical Engineering
dc.identifier.oclc1036985342en_US


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record