MIT Libraries logoDSpace@MIT

MIT
View Item 
  • DSpace@MIT Home
  • MIT Libraries
  • MIT Theses
  • Graduate Theses
  • View Item
  • DSpace@MIT Home
  • MIT Libraries
  • MIT Theses
  • Graduate Theses
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.

Development of a motion-free tomographic imaging system

Author(s)
Cramer, Avilash (Avilash Kalpathy)
Thumbnail
DownloadFull printable version (7.843Mb)
Other Contributors
Massachusetts Institute of Technology. Department of Electrical Engineering and Computer Science.
Advisor
Elfar Adalsteinsson and Rajiv Gupta.
Terms of use
MIT theses are protected by copyright. They may be viewed, downloaded, or printed from this source but further reproduction or distribution in any format is prohibited without written permission. http://dspace.mit.edu/handle/1721.1/7582
Metadata
Show full item record
Abstract
Computed tomography (CT) is the clinical standard for diagnosing many emergent medical conditions, such as stroke and traumatic brain injuries. Unfortunately, the size, weight, and expense of CT systems make them inaccessible for patients outside of large trauma centers. We have designed a module containing multiple miniature x-ray source that would allow for CT scanners to be significantly lighter weight and cheaper, and to operate without any moving parts. This could expand access to this valuable diagnostic tool to rural and low-income communities, emergency medicine, battlefield care, and extended space missions. As part of this system, we present a photo-cathode-based x-ray source, created by depositing a thin film of magnesium on an electron amplifier. When illuminated by a UV LED, this photocathode emits a beam of electrons, with a maximum beam current of up to 500 uA per amplifier. The produced electrons are then accelerated through a high voltage to a tungsten target. These sources are individually addressable and can be pulsed rapidly, through electronic control of the LEDs. Seven of these sources comprising a 17.5 degree arc are housed together within a custom vacuum manifold. A full ring of these modules could be used for CT imaging. By turning the sources on and off one after another in series, we are able to demonstrate limited-angle x-ray tomography without any moving parts. With a clinical flat-panel detector, we demonstrate 3D reconstructions of several biological samples.
Description
Thesis: S.M., Massachusetts Institute of Technology, Department of Electrical Engineering and Computer Science, 2018.
 
Cataloged from PDF version of thesis.
 
Includes bibliographical references (pages 71-77).
 
Date issued
2018
URI
http://hdl.handle.net/1721.1/117457
Department
Massachusetts Institute of Technology. Department of Electrical Engineering and Computer Science
Publisher
Massachusetts Institute of Technology
Keywords
Electrical Engineering and Computer Science.

Collections
  • Graduate Theses

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

My Account

Login

Statistics

OA StatisticsStatistics by CountryStatistics by Department
MIT Libraries
PrivacyPermissionsAccessibilityContact us
MIT
Content created by the MIT Libraries, CC BY-NC unless otherwise noted. Notify us about copyright concerns.