Quantifying fluid overload with portable magnetic resonance sensors

Author(s)
Colucci, Lina Avancini
Thumbnail
DownloadFull printable version (23.38Mb)
Other Contributors
Harvard--MIT Program in Health Sciences and Technology.
Advisor
Michael J. Cima.
Terms of use
MIT theses are protected by copyright. They may be viewed, downloaded, or printed from this source but further reproduction or distribution in any format is prohibited without written permission. http://dspace.mit.edu/handle/1721.1/7582
Metadata
Show full item record
Abstract
The objective of this work was to translate the diagnostic capabilities of magnetic resonance imaging (MRI) to the patient bedside, specifically for the purpose of quantifying fluid overload. MRI is used extensively in clinical medicine, but it is still not used for routine diagnostics due to high cost, limited availability, and long scan times. Many of these impracticalities come from the hardware requirements associated with generating images. Images, however, are not necessary to harness some of magnetic resonance's (MR's) diagnostic potential. This thesis demonstrates that that a single-voxel MR sensor can obtain the same results as a traditional MRI in both phantoms and humans. A clinical study with hemodialysis patients and age-matched healthy controls was performed at MGH. The T2 relaxation times of study participants' legs were quantified at multiple time points with both a 1.5T clinical MRI scanner and a custom 0.27T single-voxel MR sensor. The results showed that the first sign of fluid overload is an increase in the relative fraction of extracellular fluid in the muscle. The relaxation time of the extracellular fluid in the muscle eventually increases after more fluid accumulates. Importantly, these MR findings occur before signs of lower-extremity edema are detectable on physical exam. Two healthy control subjects became dehydrated over the course of the study and the relative fraction of their extracellular fluid decreased. This incidental finding suggests MR can measure the full spectrum of hydration states. Furthermore, a single MRI measurement at a single time point can distinguish fluid overloaded patients from healthy controls. The amplitude associated with extracellular fluid most closely correlates to fluid loss, and these amplitude decreases are detectable with both the MRI and MR sensor. The results of this work point towards a promising future of using cheaper, faster MR sensors for bedside diagnostics.
Description
Thesis: Ph. D. in Medical Engineering and Medical Physics, Harvard-MIT Program in Health Sciences and Technology, 2018.
 
Cataloged from PDF version of thesis.
 
Includes bibliographical references (pages 163-173).
 
Date issued
2018
URI
http://hdl.handle.net/1721.1/117894
Department
Harvard University--MIT Division of Health Sciences and Technology
Publisher
Massachusetts Institute of Technology
Keywords
Harvard--MIT Program in Health Sciences and Technology.

Collections
  • Doctoral Theses

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

My Account

Login

Statistics

OA StatisticsStatistics by CountryStatistics by Department
MIT Libraries
PrivacyPermissionsAccessibilityContact us
MIT
Content created by the MIT Libraries, CC BY-NC unless otherwise noted. Notify us about copyright concerns.