Design and development of a smart, self-contained, portable negative pressure wound therapy device

Author(s)
Modak, Ashin (Ashin Pramod)
Thumbnail
DownloadFull printable version (17.59Mb)
Other Contributors
Massachusetts Institute of Technology. Department of Mechanical Engineering.
Advisor
Ian W. Hunter.
Terms of use
MIT theses are protected by copyright. They may be viewed, downloaded, or printed from this source but further reproduction or distribution in any format is prohibited without written permission. http://dspace.mit.edu/handle/1721.1/7582
Metadata
Show full item record
Abstract
Negative pressure wound therapy (NPWT) is a commonly used treatment in which the application of a low vacuum (-20kPa) is used to accelerate the recovery of chronic, hard-to-heal wounds. Costs of chronic wounds such as diabetic foot ulcers are estimated to be $25 billion, with 6.5 million patients being affected. Improving the portability and efficacy of NPWT devices will allow a larger migration of patients from hospital stays to at-home care. Current portable NPWT devices have severe limitations due to their size, inability to dynamically modulate pressure or handle large volumes of wound exudate. The work in this thesis was to develop a more portable NPWT device in which all functional components are self-contained within the bandage itself. To accomplish this goal, a soft-material, fuel-cell based actuator was designed and incorporated into a self contained, compact pumping mechanism. Additionally graphene-oxide barriers were designed to allow for fluid management at the wound site. The designed bandage was able to maintain negative pressure even at worst-case scenario leak rates (6.7 x 102 mL/s) and an exudate rate of 5.6 x 10-5 mL/s. The contributions from this thesis are a novel, soft-materials based actuator for use in biomedical applications and the further characterization of graphene-oxide barriers.
Description
Thesis: Ph. D., Massachusetts Institute of Technology, Department of Mechanical Engineering, 2018.
 
Cataloged from PDF version of thesis.
 
Includes bibliographical references (pages 137-143).
 
Date issued
2018
URI
http://hdl.handle.net/1721.1/119769
Department
Massachusetts Institute of Technology. Department of Mechanical Engineering
Publisher
Massachusetts Institute of Technology
Keywords
Mechanical Engineering.

Collections
  • Doctoral Theses

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

My Account

Login

Statistics

OA StatisticsStatistics by CountryStatistics by Department
MIT Libraries
PrivacyPermissionsAccessibilityContact us
MIT
Content created by the MIT Libraries, CC BY-NC unless otherwise noted. Notify us about copyright concerns.