dc.identifier.urihttp://hdl.handle.net/1721.1/120122
dc.description.abstractAn improved tool for operative vaginal delivery can reduce maternal and fetal trauma during the delivery and recovery processes. When a delivery cannot be completed naturally due to maternal exhaustion or fetal distress, physicians must perform an operative vaginal delivery (OVD), with forceps or a vacuum, or a Cesarean section (C-section). Although C-sections are more prevalent in the United States than OVDs, they require longer maternal hospital stays and recovery time and increase risk of maternal infection and fetal breathing problems. In 2015, the American College of Obstetrics and Gynecology pushed to increase the number of OVDs to limit C-section associated delivery risks. However, the current tools for OVD either have steep learning curves, are unable to be used for all fetal head presentations, or have associated maternal and fetal risks. There is a need for an easy to use, safe, and reliable tool for operative vaginal delivery. Topics: Feedback, Rotation, Sensors, Vacuum, Gynecology, Obstetrics, Risken_US
dc.publisherAmerican Society of Mechanical Engineersen_US
dc.relation.isversionofhttp://dx.doi.org/10.1115/DMD2018-6859en_US
dc.rightsArticle is made available in accordance with the publisher's policy and may be subject to US copyright law. Please refer to the publisher's site for terms of use.en_US
dc.sourceASMEen_US
dc.titleObstetrical Forceps With Passive Rotation and Sensor Feedbacken_US
dc.typeArticleen_US
dc.identifier.citationBeaudoin, Judith M., Lillian T. Chin, Hannah M. Zlotnick, Thomas M. Cervantes, Alexander H. Slocum, Julian N. Robinson, and Sarah C. Lassey. “Obstetrical Forceps With Passive Rotation and Sensor Feedback.” Proceedings of the 2018 Design of Medical Devices Conference, 9-12 April, 2018, Minneapolis, Minnesota, USA, ASME, 2018. © 2018 ASMEen_US
dc.contributor.departmentMassachusetts Institute of Technology. Department of Biological Engineeringen_US
dc.contributor.departmentMassachusetts Institute of Technology. Department of Electrical Engineering and Computer Scienceen_US
dc.contributor.departmentMassachusetts Institute of Technology. Department of Mechanical Engineeringen_US
dc.contributor.mitauthorBeaudoin, Judith Michelle
dc.contributor.mitauthorChin, Lillian T.
dc.contributor.mitauthorZlotnick, Hannah M.
dc.contributor.mitauthorCervantes, Thomas Michael
dc.contributor.mitauthorSlocum, Alexander H
dc.relation.journalProceedings of the 2018 Design of Medical Devices Conferenceen_US
dc.eprint.versionFinal published versionen_US
dc.type.urihttp://purl.org/eprint/type/ConferencePaperen_US
eprint.statushttp://purl.org/eprint/status/NonPeerRevieweden_US
dc.date.updated2019-01-02T19:20:44Z
dspace.orderedauthorsBeaudoin, Judith M.; Chin, Lillian T.; Zlotnick, Hannah M.; Cervantes, Thomas M.; Slocum, Alexander H.; Robinson, Julian N.; Lassey, Sarah C.en_US
dspace.embargo.termsNen_US
dc.identifier.orcidhttps://orcid.org/0000-0003-4083-5275
dc.identifier.orcidhttps://orcid.org/0000-0002-5048-4109
mit.licensePUBLISHER_POLICYen_US


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record