Show simple item record

dc.contributor.advisorRegina Barzilay.en_US
dc.contributor.authorYordán López, Fernando A.en_US
dc.contributor.otherMassachusetts Institute of Technology. Department of Electrical Engineering and Computer Science.en_US
dc.date.accessioned2019-07-15T20:30:29Z
dc.date.available2019-07-15T20:30:29Z
dc.date.copyright2018en_US
dc.date.issued2018en_US
dc.identifier.urihttps://hdl.handle.net/1721.1/121644
dc.descriptionThis electronic version was submitted by the student author. The certified thesis is available in the Institute Archives and Special Collections.en_US
dc.descriptionThesis: M. Eng., Massachusetts Institute of Technology, Department of Electrical Engineering and Computer Science, 2018en_US
dc.descriptionCataloged from student-submitted PDF version of thesis.en_US
dc.descriptionIncludes bibliographical references (pages 59-62).en_US
dc.description.abstractArm lymphedema is a debilitating condition characterized by a large swelling of the patient arms. This thesis describes a system for measuring arm volume with the goal of providing a cost-effective, reliable, easy to use, comfortable, and informative alternative to the tedious water displacement method or the expensive perometer. The device consists of 8 inexpensive positionally fixed realsense sr300 depth cameras in a frame that can be placed on a flat surface, and used to scan a patient's arm in order to build a 3D mesh that can be used to extract not only the total volume of the arm but also the volume of specific segments. A special focus is given to the method of global registration of each camera's depth image, where camera positions are iteratively adjusted by applying ICP between one camera's point cloud and the point cloud generated by all-but-that-one camera. The system is then validated by taking a set of measurements of a human arm and comparing the values against those obtained from the water displacement method, in addition to also measuring objects of known volume and comparing those values with the ground truth. Despite a large non constant percentage error between expected and obtained values, early experiments show an 5_ correlation value of .99 between the expected and measured volumes. While additional work and experiments are needed to guarantee the reliability of this proposed method in order to be used in a clinical setting, these early findings show the potential of using such a system in small clinics where both space and money limits the accessibility of a large or expensive device. Keywords: lymphedema, global registration, realsense, point cloud alignment, volume measurement, 3D reconstructionen_US
dc.description.statementofresponsibilityby Fernando A. Yordán López.en_US
dc.format.extent62 pagesen_US
dc.language.isoengen_US
dc.publisherMassachusetts Institute of Technologyen_US
dc.rightsMIT theses are protected by copyright. They may be viewed, downloaded, or printed from this source but further reproduction or distribution in any format is prohibited without written permission.en_US
dc.rights.urihttp://dspace.mit.edu/handle/1721.1/7582en_US
dc.subjectElectrical Engineering and Computer Science.en_US
dc.titlePoint cloud alignment in arm reconstruction for lymphedema detection by iterating pairwise ICPen_US
dc.typeThesisen_US
dc.description.degreeM. Eng.en_US
dc.contributor.departmentMassachusetts Institute of Technology. Department of Electrical Engineering and Computer Scienceen_US
dc.identifier.oclc1098215596en_US
dc.description.collectionM.Eng. Massachusetts Institute of Technology, Department of Electrical Engineering and Computer Scienceen_US
dspace.imported2019-07-15T20:30:27Zen_US
mit.thesis.degreeMasteren_US
mit.thesis.departmentEECSen_US


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record