Show simple item record

dc.contributor.advisorOtto K. Harling.en_US
dc.contributor.authorRiley, Kent J.(Kent Jason)en_US
dc.contributor.otherMassachusetts Institute of Technology. Department of Nuclear Engineering.en_US
dc.date.accessioned2019-12-02T22:51:28Z
dc.date.available2019-12-02T22:51:28Z
dc.date.copyright2001en_US
dc.date.issued2001en_US
dc.identifier.urihttps://hdl.handle.net/1721.1/123100
dc.descriptionThesis (Ph. D.)--Massachusetts Institute of Technology, Dept. of Nuclear Engineering, 2001.en_US
dc.descriptionIncludes bibliographical references.en_US
dc.description.abstractThis study demonstrates the first successful implementation of a fission converter to produce a source of epithermal neutrons suitable for BNCT. The final design, construction and characterization of a new epithermal neutron beam is presented. A high intensity source with low contamination is obtained using a fission converter driven by thermal neutrons from the MIT research reactor. The facility is housed in the experimental hall and operates in parallel with other user applications. The fission converter is powered by 10 spent MITR-II fuel elements and employs resonance scattering filters with thermal neutron absorbers to tailor the neutron energy distribution. A lead shield attenuates photon contamination in the beam and lead collimators direct the neutron beam toward the patient. A horizontal beamline leads to the new medical room which is built with 1.1 m thick, high density concrete walls and is large enough to permit various treatment configurations. Ambient dose equivalent rates outside the shielded room are < I mrem/hr with the converter operating at full power and do not interfere with other experimental users and reactor operations.en_US
dc.description.abstract(cont.) Beam delivery is controlled with three in-line shutters that allow unrestricted access to the medical room while the reactor is at full power. Patient irradiations are controlled by redundant programmable logic controllers that automatically close the beam shutters when the prescribed monitor counts have been accumulated. Measurements were performed on central axis to assess beam performance. An in-air epithermal neutron flux of 8.4 +/- 0.8 E+09 n/cm2s was obtained with concomitant fast neutron and photon absorbed dose rates of 3.9 +/- 0.5 and 11.8 +/- 0.8 cGy/min. Depth dose profiles measured in-phantom are in general agreement with those determined from Monte Carlo calculations and indicate that normal tissue tolerance can be reached in treatment times of less than 10 minutes. The in-beam fast neutron and photon contaminants account for less than 10% of the dose received by normal tissue surrounding the target volume, which approaches the clinical optimum.en_US
dc.description.statementofresponsibilityby Kent J. Riley.en_US
dc.format.extent2 v. ([710] p.)en_US
dc.publisherMassachusetts Institute of Technologyen_US
dc.rightsMIT theses are protected by copyright. They may be viewed, downloaded, or printed from this source but further reproduction or distribution in any format is prohibited without written permission.en_US
dc.rights.urihttp://dspace.mit.edu/handle/1721.1/7582en_US
dc.subjectNuclear Engineering.en_US
dc.titleConstruction and characterization of a fission converter based epithermal neutron beam for BNCTen_US
dc.typeThesisen_US
dc.contributor.departmentMassachusetts Institute of Technology. Department of Nuclear Engineeringen_US
dc.contributor.departmentMassachusetts Institute of Technology. Department of Nuclear Science and Engineering
dc.identifier.oclc49725089en_US
dc.description.collectionThesis (Ph. D.)--Massachusetts Institute of Technology, Dept. of Nuclear Engineering, 2001.en_US
dspace.imported2019-12-02T22:51:27Zen_US
mit.thesis.degreeDoctoralen_US
mit.thesis.departmentNucEngen_US


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record