Show simple item record

dc.contributor.advisorHugh Herr.en_US
dc.contributor.authorPalmer, Jasmin Elena.en_US
dc.contributor.otherMassachusetts Institute of Technology. Department of Mechanical Engineering.en_US
dc.date.accessioned2019-12-13T18:58:40Z
dc.date.available2019-12-13T18:58:40Z
dc.date.copyright2019en_US
dc.date.issued2019en_US
dc.identifier.urihttps://hdl.handle.net/1721.1/123272
dc.descriptionThesis: S.B., Massachusetts Institute of Technology, Department of Mechanical Engineering, 2019en_US
dc.descriptionCataloged from PDF version of thesis.en_US
dc.descriptionIncludes bibliographical references (page 46).en_US
dc.description.abstractThis thesis seeks to explore passive designs for a mechanical alternative to the metatarsophalangeal (MTP) joint, a critical anatomical component in human feet which allows for various types of anatomical motion. Our goal is to design a system that will act as a platform to test a proof of concept for a passive ankle-foot prosthesis with an MTP joint, but can also be adapted to use an actuated joint in the future. To increase the user's range of motion, our aim was for the mechanical MTP joint to achieve a maximum 600 dorsiflexion angle. We developed 2 MTP joint designs (Rubber Hinge and Fabric Hinge) with 2 body geometries varying at the heel for each (Traditional Heel and Inverted Heel) for a total of 4 models. We performed a static load Finite Element Analysis (FEA) using the Solidworks FEA Simulation Tool. The FEA was performed under the worst-case static load scenarios for the toe and body components of the prosthesis, standing on tiptoe with a dorsiflexion angle of 60' for the toe components and standing with all weight on the heel for the body components. The simulation yielded that not only did no components experience any irreversible deformation, but that the Rubber Hinge design had a minimum safety factor of 5.7, 10, and 4.5 for the Toe, Inverted Heel Body, and Traditional Heel Body respectively and the Fabric Hinge Design had a minimum safety factor 1.4, 9.9 and 4.5 for the Toe, Inverted Heel Body, and Traditional Heel Body respectively. This informed us that though both designs did not undergo failure under the prescribed loads, material utilization was in excess and could be further optimized to decrease the weight. Future designers should focus on implementing this platform into high fidelity physical models to be tested under various static and dynamic loading conditions as well as further optimizing the dimensions of the prosthesis.en_US
dc.description.statementofresponsibilityby Jasmin Elena Palmer.en_US
dc.format.extent46 pagesen_US
dc.language.isoengen_US
dc.publisherMassachusetts Institute of Technologyen_US
dc.rightsMIT theses are protected by copyright. They may be viewed, downloaded, or printed from this source but further reproduction or distribution in any format is prohibited without written permission.en_US
dc.rights.urihttp://dspace.mit.edu/handle/1721.1/7582en_US
dc.subjectMechanical Engineering.en_US
dc.titleDesign and development of mechanical metatarsophalangeal joint for powered ankle-foot prosthesesen_US
dc.title.alternativeMechanical MTP joint for powered ankle-foot prosthesesen_US
dc.typeThesisen_US
dc.description.degreeS.B.en_US
dc.contributor.departmentMassachusetts Institute of Technology. Department of Mechanical Engineeringen_US
dc.identifier.oclc1130229198en_US
dc.description.collectionS.B. Massachusetts Institute of Technology, Department of Mechanical Engineeringen_US
dspace.imported2019-12-13T18:58:39Zen_US
mit.thesis.degreeBacheloren_US
mit.thesis.departmentMechEen_US


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record