dc.descriptionIncludes bibliographical references (pages 63-65).en_US
dc.description.abstractSteam generators are an essential component in nuclear power plants which serve to transfer thermal power from a liquid coolant to steam by boiling water. Even with many advancements in the designs of steam generators, they still require extremely large sizes and have high costs which are major hurdles for the implementation of new reactor designs such as Small Modular Reactors. Using a Printed Circuit Heat Exchanger (PCHE) such as those from the company HeatricTM as a steam generator to boil the liquid in the secondary side has potential to overcome the disadvantages of conventional steam generators. Computational Fluid Dynamics was used to aid the assessment of such compact steam generator. The models used were bench marked against a 1-D MATLAB code which simulated a compact steam generator with straight, semi-circular channels. The same conditions were used to simulate a zig-zag, semi-circular PCHE. The zig-zag configuration resulted in a 22 °C increase in superheat over the straight channel configuration at the cost of pressure drops that are over 4 times higher but yet easily accommodated. The PCHE was also simulated in different orientations with respect to gravity and determined there is little advantage in using a vertical layout regarding pressure drop for the zig-zag configuration. Plugging of a single channel was also simulated to determine the effect on surrounding channels and potential hot spots.en_US
dc.description.statementofresponsibilityby Brandon Ariel Aranda Ocampo.en_US
dc.format.extent65 pagesen_US
dc.language.isoengen_US
dc.publisherMassachusetts Institute of Technologyen_US
dc.rightsMIT theses may be protected by copyright. Please reuse MIT thesis content according to the MIT Libraries Permissions Policy, which is available through the URL provided.en_US
dc.rights.urihttp://dspace.mit.edu/handle/1721.1/7582en_US
dc.subjectNuclear Science and Engineering.en_US
dc.titleAssessment of a compact steam generator aided by computational fluid dynamicsen_US
dc.typeThesisen_US
dc.description.degreeS.B.en_US
dc.contributor.departmentMassachusetts Institute of Technology. Department of Nuclear Science and Engineeringen_US
dc.identifier.oclc1191905265en_US
dc.description.collectionS.B. Massachusetts Institute of Technology, Department of Nuclear Science and Engineeringen_US
dspace.imported2020-09-15T21:51:33Zen_US
mit.thesis.degreeBacheloren_US
mit.thesis.departmentNucEngen_US


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record