dc.description.abstractThe Power Electric Building Block (PEBB) 6000 is a shipboard power converter unit developed by the Navy's Electric Ship Research and Development Consortium (ESRDC). Cooling strategies for the PEBB 6000 are constrained by its size, accessibility, and high heat flux. This paper proposes an air heat exchanger design that combines a parallel plate-fin heat sink with air jet impingement onto its fins. Previous studies showed that jet impingement methods can yield heat transfer rates that are three times of those produced by conventional cooling methods, which confines a parallel flow to a surface. In order to evaluate the design feasibility of a multi-jet impingement air heat exchanger, this paper simulates the temperature contours and the flow trajectories for various multi-jet impingement models using SOLIDWORKS Flow Simulation in two stages. First, multi-jet impingement models with varying number of nozzles, nozzle diameters, impingement heights, arrangements, and velocity configurations were simulated for a single parallel plate fin. Cooler fin temperatures were achieved with larger diameter size, smaller impingement height, higher inlet velocity, and more nozzles. In the second stage, a model for the multi-jet air heat exchanger was created. When compared with simulation results for the heat sink with conventional parallel air flow, the fin thermal resistance of the heat sink was reduced by approximately 60 percent and the heat transfer rate was increased by almost threefold with the multi-jet impingement heat exchanger setup. These results help assess the potential of using a multi-jet impingement heat exchanger to cool the PEBB and provide valuable insight to improve future models.en_US
dc.description.statementofresponsibilityby Qingmei Wu.en_US
dc.format.extent59 pagesen_US
dc.language.isoengen_US
dc.publisherMassachusetts Institute of Technologyen_US
dc.rightsMIT theses may be protected by copyright. Please reuse MIT thesis content according to the MIT Libraries Permissions Policy, which is available through the URL provided.en_US
dc.rights.urihttp://dspace.mit.edu/handle/1721.1/7582en_US
dc.subjectMechanical Engineering.en_US
dc.titleEvaluating a multi-jet Impingement air heat exchanger design for PEBB 6000 using Solidworks Flow Simulationen_US
dc.typeThesisen_US
dc.description.degreeS.B.en_US
dc.contributor.departmentMassachusetts Institute of Technology. Department of Mechanical Engineeringen_US
dc.identifier.oclc1196823625en_US
dc.description.collectionS.B. Massachusetts Institute of Technology, Department of Mechanical Engineeringen_US
dspace.imported2020-10-08T21:27:44Zen_US
mit.thesis.degreeBacheloren_US
mit.thesis.departmentMechEen_US


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record