| dc.contributor.advisor | Steven B. Leeb and Daisy Green. | en_US |
| dc.contributor.author | Camenzind, Kathy(Katherine A.) | en_US |
| dc.contributor.other | Massachusetts Institute of Technology. Department of Electrical Engineering and Computer Science. | en_US |
| dc.date.accessioned | 2020-10-08T21:29:55Z | |
| dc.date.available | 2020-10-08T21:29:55Z | |
| dc.date.copyright | 2020 | en_US |
| dc.date.issued | 2020 | en_US |
| dc.identifier.uri | https://hdl.handle.net/1721.1/127909 | |
| dc.description | Thesis: M. Eng., Massachusetts Institute of Technology, Department of Electrical Engineering and Computer Science, May, 2020 | en_US |
| dc.description | Cataloged from the official PDF of thesis. | en_US |
| dc.description | Includes bibliographical references (pages 117-119). | en_US |
| dc.description.abstract | Non-contact voltage monitoring involves continuously measuring conductor voltages without contacting the conductors. This thesis explores several methods of using parasitic capacitive coupling to monitor AC voltages in three-phase power cables. Using an existing sensor architecture, three-phase line voltages are accurately reconstructed through intrusive calibration techniques. Experimental results are presented for measuring 60 Hz line voltages using high-frequency calibration. This thesis also describes a new method of voltage monitoring, presenting a new circuit designed to monitor line-line voltages without requiring intrusive control of or injection onto the line voltages during calibration. Analysis and simulation of this system is shown, demonstrating accurate reconstruction for reasonably balanced line-line voltages. | en_US |
| dc.description.statementofresponsibility | by Kathy Camenzind. | en_US |
| dc.format.extent | 186 pages | en_US |
| dc.language.iso | eng | en_US |
| dc.publisher | Massachusetts Institute of Technology | en_US |
| dc.rights | MIT theses may be protected by copyright. Please reuse MIT thesis content according to the MIT Libraries Permissions Policy, which is available through the URL provided. | en_US |
| dc.rights.uri | http://dspace.mit.edu/handle/1721.1/7582 | en_US |
| dc.subject | Electrical Engineering and Computer Science. | en_US |
| dc.title | Non-contact voltage monitoring of three-phase power cables | en_US |
| dc.type | Thesis | en_US |
| dc.description.degree | M. Eng. | en_US |
| dc.contributor.department | Massachusetts Institute of Technology. Department of Electrical Engineering and Computer Science | en_US |
| dc.identifier.oclc | 1197630053 | en_US |
| dc.description.collection | M.Eng. Massachusetts Institute of Technology, Department of Electrical Engineering and Computer Science | en_US |
| dspace.imported | 2020-10-08T21:29:54Z | en_US |
| mit.thesis.degree | Master | en_US |
| mit.thesis.department | EECS | en_US |