Show simple item record

dc.contributor.advisorHugh M. Herr.en_US
dc.contributor.authorTaylor, Cameron Roy.en_US
dc.contributor.otherProgram in Media Arts and Sciences (Massachusetts Institute of Technology)en_US
dc.date.accessioned2021-03-22T17:23:13Z
dc.date.available2021-03-22T17:23:13Z
dc.date.copyright2020en_US
dc.date.issued2020en_US
dc.identifier.urihttps://hdl.handle.net/1721.1/130210
dc.descriptionThesis: Ph. D., Massachusetts Institute of Technology, School of Architecture and Planning, Program in Media Arts and Sciences, May, 2020en_US
dc.descriptionCataloged from student-submitted PDF of thesis.en_US
dc.descriptionIncludes bibliographical references (pages 111-113).en_US
dc.description.abstractTarget tracking is necessary across a wide range of disciplines and scales, such as in monitoring tissues and cells, beam bending, fluid dynamics, human-computer interaction, and traffic. Due to these widespread applications, advances in target tracking drive cascades of new medical, social, and scientific capabilities. In particular, this dissertation advances magnetomicrometry, a technology that tracks visually-obscured magnetic beads implanted within biological tissue to monitor in-vivo tissue length and speed within freely moving animals and humans. There are many methods to track visually-obscured objects, but magnetic-target tracking has the advantages of being low-cost, portable, and safe. However, current magnet tracking technologies are slow, precluding high-speed real-time magnetic-target tracking. This is due to the mathematics of magnet tracking, whereby magnet positions are traditionally determined via numerical optimization, suffering from instability and significant delays. This dissertation develops the mathematics for an improved method to track one or more magnets with high speed and accuracy and validates this method by demonstrating real-time muscle length tracking. We develop a high-speed, real-time, multiple-magnetic-target tracking method using the analytic gradient of the magnetic field prediction error. We extend this method to compensate for magnetic disturbances in real time using a simpler, more portable strategy than currently-published disturbance compensation methods. Validating our method in a physical system against state-of-the-art motion capture, we demonstrate increased maximum bandwidths of 336%, 525%, 635%, and 773% for the simultaneous tracking of 1, 2, 3, and 4 magnets, respectively, with tracking accuracy comparable to state-of-the-art magnet tracking.en_US
dc.description.statementofresponsibilityby Cameron Roy Taylor.en_US
dc.format.extent113 pagesen_US
dc.language.isoengen_US
dc.publisherMassachusetts Institute of Technologyen_US
dc.rightsMIT theses may be protected by copyright. Please reuse MIT thesis content according to the MIT Libraries Permissions Policy, which is available through the URL provided.en_US
dc.rights.urihttp://dspace.mit.edu/handle/1721.1/7582en_US
dc.subjectProgram in Media Arts and Sciencesen_US
dc.titleMagnetomicrometry : tissue length tracking via implanted magnetic beadsen_US
dc.typeThesisen_US
dc.description.degreePh. D.en_US
dc.contributor.departmentProgram in Media Arts and Sciences (Massachusetts Institute of Technology)en_US
dc.identifier.oclc1241255173en_US
dc.description.collectionPh.D. Massachusetts Institute of Technology, School of Architecture and Planning, Program in Media Arts and Sciencesen_US
dspace.imported2021-03-22T17:22:42Zen_US
mit.thesis.degreeDoctoralen_US
mit.thesis.departmentMediaen_US


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record