Show simple item record

dc.contributor.authorGoldfinger, D. C
dc.contributor.authorAdams, J. S
dc.contributor.authorBaker, R.
dc.contributor.authorBandler, S. R
dc.contributor.authorBastidon, N.
dc.contributor.authorDanowski, M. E
dc.contributor.authorDoriese, W. B
dc.contributor.authorEckart, M. E
dc.contributor.authorFigueroa-Feliciano, E.
dc.contributor.authorHeine, S. N T
dc.contributor.authorHilton, G. C
dc.contributor.authorHubbard, A. J F
dc.contributor.authorKelley, R. L
dc.contributor.authorKilbourne, C. A
dc.contributor.authorManzagol-Harwood, R. E
dc.contributor.authorMcCammon, D.
dc.date.accessioned2022-05-27T14:58:14Z
dc.date.available2021-09-20T17:17:22Z
dc.date.available2022-05-27T14:58:14Z
dc.date.issued2018-09
dc.date.submitted2017-11
dc.identifier.issn1573-7357
dc.identifier.issn0022-2291
dc.identifier.urihttps://hdl.handle.net/1721.1/131510.2
dc.description.abstractAbstract Micro-X is a sounding rocket-borne X-ray telescope that uses a transition edge sensor microcalorimeter array to provide high-energy-resolution spectroscopy. Micro-X is a versatile instrument with plans to observe the Puppis A supernova remnant during its first flight, as well as future observations of the Milky Way to search for X-ray signals from decaying dark matter. Commissioning and functionality testing are complete, and the thermal performance of the system has been validated. We are currently evaluating the detector performance in the flight cryostat with the flight multiplexing electronics. Operating in this setup has allowed us to characterize sources of detector and readout noise, as well as to implement mitigation techniques to improve performance in anticipation of the upcoming flight. We present an overview of important noise considerations in addition to an update on latest detector performance.en_US
dc.publisherSpringer USen_US
dc.relation.isversionofhttps://doi.org/10.1007/s10909-018-2060-7en_US
dc.rightsArticle is made available in accordance with the publisher's policy and may be subject to US copyright law. Please refer to the publisher's site for terms of use.en_US
dc.sourceSpringer USen_US
dc.titleDetector Calibration for the Micro-X Sounding Rocket X-ray Telescopeen_US
dc.typeArticleen_US
dc.contributor.departmentMassachusetts Institute of Technology. Department of Physics
dc.relation.journalJournal of Low Temperature Physicsen_US
dc.eprint.versionAuthor's final manuscripten_US
dc.type.urihttp://purl.org/eprint/type/JournalArticleen_US
eprint.statushttp://purl.org/eprint/status/PeerRevieweden_US
dc.date.updated2020-09-24T21:27:26Z
dc.language.rfc3066en
dc.rights.holderSpringer Science+Business Media, LLC, part of Springer Nature
dspace.embargo.termsY
dspace.date.submission2020-09-24T21:27:26Z
mit.licensePUBLISHER_POLICY
mit.metadata.statusAuthority Work Neededen_US


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record

VersionItemDateSummary

*Selected version