A multispectral imaging method and device to detect and quantify the presence of fluid in the middle ear to facilitate the diagnosis and triage of ear infections

Author(s)
Rajamanickam, Gokul Prasath.
Thumbnail
Download1263245354-MIT.pdf (3.834Mb)
Other Contributors
Massachusetts Institute of Technology. Engineering and Management Program.
System Design and Management Program.
Terms of use
MIT theses may be protected by copyright. Please reuse MIT thesis content according to the MIT Libraries Permissions Policy, which is available through the URL provided. http://dspace.mit.edu/handle/1721.1/7582
Metadata
Show full item record
Abstract
Middle ear infections or otitis media that cause inflammation of tympanic membrane and fluid buildup in the middle ear cavity accounts for 2-3 million hospital visits every year [34]. As per an epidemiological study conducted from 2006 - 2016 on 685 children, between the ages of 1-3 years, roughly 60% had at least one hospital visit due to ear infections [3]. Despite the high incidence, the diagnosis of otitis media is only 50% accurate (a coin toss) due to the subjective nature of diagnosis as the physicians look at the ear drum and detect the fluid behind the ear drum. To detect the fluid with high sensitivity and accurately diagnose middle ear infection, we propose a multispectral visible - nIR otoscope that operates in the range of 600 nm - 1050 nm. We have performed experiments to demonstrate the proof of concept of our device on phantoms that includes, 3D printed middle ear structure, tympanic membrane made of silicone, and orange juice as ear fluid all of which mimics the properties of human ear. The multispectral otoscope showed highest contrast between ossicles and fluid at 1000 nm which shows low attenuation of fluid and tympanic membrane at NIR wavelengths. The system is calibrated against a diffuse reflection surface to account for variations in source and detector. Our experiments showed that empty phantoms yielded almost equal contrast across the entire visible- NIR wavelength. Once the fluid is filled, the contrast increased by 30 ± 10 % in the visible wavelength (600 nm - 750 nm) and 120 ± 20 % in nIR wavelength (900 nm - 1000 nm). This 80% - 100% difference in contrast between visible and NIR wavelength is used to detect and highlight the areas of the middle ear filled with fluid.
Description
Thesis: S.M. in Engineering and Management, Massachusetts Institute of Technology, System Design and Management Program, May, 2020
 
Cataloged from the official version of thesis. Page 68 blank.
 
Includes bibliographical references (pages 65-67).
 
Date issued
2020
URI
https://hdl.handle.net/1721.1/132857
Department
Massachusetts Institute of Technology. Engineering and Management Program
Publisher
Massachusetts Institute of Technology
Keywords
Engineering and Management Program., System Design and Management Program.

Collections
  • Graduate Theses

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

My Account

Login

Statistics

OA StatisticsStatistics by CountryStatistics by Department
MIT Libraries homeMIT Libraries logo

Find us on

Twitter Facebook Instagram YouTube RSS

MIT Libraries navigation

SearchHours & locationsBorrow & requestResearch supportAbout us
PrivacyPermissionsAccessibility
MIT
Massachusetts Institute of Technology
Content created by the MIT Libraries, CC BY-NC unless otherwise noted. Notify us about copyright concerns.