MIT Libraries logoDSpace@MIT

MIT
View Item 
  • DSpace@MIT Home
  • MIT Libraries
  • MIT Theses
  • Graduate Theses
  • View Item
  • DSpace@MIT Home
  • MIT Libraries
  • MIT Theses
  • Graduate Theses
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.

Shipboard Fault Detection, Marine Micro-Grid Power Diagnostics and Vessel Ventilation Monitoring

Author(s)
O'Connell, Joseph William
Thumbnail
DownloadThesis PDF (16.96Mb)
Advisor
Leeb, Steven B.
Green, Daisy Hikari
Terms of use
In Copyright - Educational Use Permitted Copyright MIT http://rightsstatements.org/page/InC-EDU/1.0/
Metadata
Show full item record
Abstract
Non-intrusive load monitoring has proven its utility for equipment history logging, activity tracking, condition based maintenance, fault detection & diagnostics and energy scorekeeping through numerous installations on various Navy and Coast Guard vessels throughout the last several decades. Using equipment power transients to identify particular equipment operation, and tracking these transients enables a non-intrusive load monitor (NILM) to ‘learn’ healthy load behavior. Changes in transient behavior is indicative of soft faults and potentially progressive failure, which a NILM can alert watch-standers to. Technological upgrades to the NILM prototype have enabled timely installations and calibrations, which provide further evidence for their utility as either alternatives or redundant systems to traditional machinery control and monitoring software (MCMS). Over the past two years prototype installations have accelerated with installations occurring on Coast Guard Cutters MARLIN (WPB-87304) and THUNDER BAY (WTGB-108) and the Navy’s USS INDIANAPOLIS (LCS-17). These installations have provided valuable data, and proven that NILM can successfully disaggregrate, analyze, characterize and identify various engineering equipment. Particular research was focused on marine heating ventilation and air-conditioning (HVAC) systems, with the development of a framework for ventilation diagnostics. A NILM is able to effectively identify fan operation and historical power draw, using aggregate power consumption as a proxy for ventilation cleanliness. Additionally, current data can be analyzed and processed to yield slot harmonics, enabling the NILM to track fan speeds in real time, as well as other induction motor driven loads.
Date issued
2021-06
URI
https://hdl.handle.net/1721.1/139363
Department
Massachusetts Institute of Technology. Department of Mechanical Engineering
Publisher
Massachusetts Institute of Technology

Collections
  • Graduate Theses

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

My Account

Login

Statistics

OA StatisticsStatistics by CountryStatistics by Department
MIT Libraries
PrivacyPermissionsAccessibilityContact us
MIT
Content created by the MIT Libraries, CC BY-NC unless otherwise noted. Notify us about copyright concerns.