Safety and imaging performance of two‐channel RF shimming for fetal MRI at 3T

Author(s)
Yetisir, Filiz; Abaci Turk, Esra; Guerin, Bastien; Gagoski, Borjan A; Grant, P Ellen; Adalsteinsson, Elfar; Wald, Lawrence L; ... Show more Show less
Thumbnail
DownloadAccepted version (1.100Mb)
Open Access Policy

Open Access Policy

Creative Commons Attribution-Noncommercial-Share Alike

Terms of use
Creative Commons Attribution-Noncommercial-Share Alike http://creativecommons.org/licenses/by-nc-sa/4.0/
Metadata
Show full item record
Abstract
PURPOSE: This study investigates whether two-channel radiofrequency (RF) shimming can improve imaging without increasing specific absorption rate (SAR) for fetal MRI at 3T. METHODS: Transmit field ( B1+ ) average and variation in the fetus was simulated in seven numerical pregnant body models. Safety was quantified by maternal and fetal peak local SAR and fetal average SAR. The shim parameter space was divided into improved B1+ (magnitude and homogeneity) and improved SAR regions, and an overlap where RF shimming improved both classes of metrics compared with birdcage mode was assessed. Additionally, the effect of fetal position, tissue detail, and dielectric properties on transmit field and SAR was studied. RESULTS: A region of subject-specific RF shim parameter space improving both B1+ and SAR metrics was found for five of the seven models. Optimizing only B1+ metrics improved B1+ efficiency across models by 15% on average and 28% for the best-case model. B1+ variation improved by 26% on average and 49% for the best case. However, for these shim settings, fetal SAR increased by up to 106%. The overlap region, where both B1+ and SAR metrics improve, showed an average B1+ efficiency improvement of 6% on average across models and 19% for the best-case model. B1+ variation improved by 13% on average and 40% for the best case. RFS could also decrease maternal/fetal SAR by up to 49%/58%. CONCLUSION: RF shimming can improve imaging compared with birdcage mode without increasing fetal and maternal SAR when a patient-specific SAR model is incorporated into the shimming procedure.
Date issued
2021
URI
https://hdl.handle.net/1721.1/146522
Department
Harvard University--MIT Division of Health Sciences and Technology; Massachusetts Institute of Technology. Department of Electrical Engineering and Computer Science; Massachusetts Institute of Technology. Institute for Medical Engineering & Science
Journal
Magnetic Resonance in Medicine
Publisher
Wiley
Citation
Yetisir, Filiz, Abaci Turk, Esra, Guerin, Bastien, Gagoski, Borjan A, Grant, P Ellen et al. 2021. "Safety and imaging performance of two‐channel RF shimming for fetal MRI at 3T." Magnetic Resonance in Medicine, 86 (5).
Version: Author's final manuscript

Collections
  • MIT Open Access Articles

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

My Account

Login

Statistics

OA StatisticsStatistics by CountryStatistics by Department
MIT Libraries
PrivacyPermissionsAccessibilityContact us
MIT
Content created by the MIT Libraries, CC BY-NC unless otherwise noted. Notify us about copyright concerns.