MIT Libraries logoDSpace@MIT

MIT
View Item 
  • DSpace@MIT Home
  • MIT Libraries
  • MIT Theses
  • Doctoral Theses
  • View Item
  • DSpace@MIT Home
  • MIT Libraries
  • MIT Theses
  • Doctoral Theses
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.

A Robust and Efficient Framework for Slice-to-Volume Reconstruction: Application to Fetal MRI

Author(s)
Xu, Junshen
Thumbnail
DownloadThesis PDF (14.51Mb)
Advisor
Adalsteinsson, Elfar
Terms of use
In Copyright - Educational Use Permitted Copyright retained by author(s) https://rightsstatements.org/page/InC-EDU/1.0/
Metadata
Show full item record
Abstract
Volumetric reconstruction in presence of motion is a challenging problem in medical imaging. When imaging moving targets, many modalities are limited to fast 2D imaging techniques that provide cross-sectional snapshots (2D images) of the subject with an attempt to "freeze'' in-plane motion. However, inter-slice movement results in slice misalignment in 3D space, i.e., each image being an independent slice that fails to form a coherent volume for diagnosis and analysis. bTo this end, slice-to-volume reconstruction (SVR) has been proposed to reconstruct a high-quality 3D volume from misaligned 2D observations by performing inter-slice motion correction and super-resolution reconstruction. Existing SVR algorithms, however, have a limited capture range of slice motion and are time-consuming, particularly when producing high-resolution volumes. This thesis proposes a motion-robust and efficient machine learning framework for SVR, motivated by the application of magnetic resonance imaging (MRI) in assessing fetal brain development. We first introduce a slice-to-volume registration transformer that models input slices as a sequence and performs inter-slice motion correction by simultaneously predicting rigid transformations of all images in 3D space. We then reformulate the reconstruction problem using implicit neural representation, where the underlying volume is represented by a continuous function of 3D coordinates. This resolution-agnostic approach allows efficient reconstruction of high-resolution volumes. Finally, we extend this method to data that suffer from non-rigid motion by introducing an implicit motion field that captures slice-dependent deformation. These advances together enable robust and efficient 3D reconstruction and visualization in fetal MRI, benefiting diagnosis and downstream analysis. Additionally, the proposed framework has the potential for broader clinical implications in various applications that involve similar volumetric reconstruction problems.
Date issued
2023-06
URI
https://hdl.handle.net/1721.1/151495
Department
Massachusetts Institute of Technology. Department of Electrical Engineering and Computer Science
Publisher
Massachusetts Institute of Technology

Collections
  • Doctoral Theses

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

My Account

Login

Statistics

OA StatisticsStatistics by CountryStatistics by Department
MIT Libraries
PrivacyPermissionsAccessibilityContact us
MIT
Content created by the MIT Libraries, CC BY-NC unless otherwise noted. Notify us about copyright concerns.