MIT Libraries logoDSpace@MIT

MIT
View Item 
  • DSpace@MIT Home
  • MIT Open Access Articles
  • MIT Open Access Articles
  • View Item
  • DSpace@MIT Home
  • MIT Open Access Articles
  • MIT Open Access Articles
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.

Integration of an Aptamer-Based Signal-On Probe and a Paper-Based Origami Preconcentrator for Small Molecule Biomarkers Detection

Author(s)
Lee, Na E.; Hong, Ji H.; Lee, Seungmin; Yoo, Yong K.; Kim, Kang H.; Park, Jeong S.; Kim, Cheonjung; Yoon, Junghyo; Yoon, Dae S.; Lee, Jeong H.; ... Show more Show less
Thumbnail
Download13206_2023_119_ReferencePDF.pdf (1.214Mb)
Publisher Policy

Publisher Policy

Article is made available in accordance with the publisher's policy and may be subject to US copyright law. Please refer to the publisher's site for terms of use.

Terms of use
Article is made available in accordance with the publisher's policy and may be subject to US copyright law. Please refer to the publisher's site for terms of use.
Metadata
Show full item record
Abstract
Point-of-care testing using paper-based lateral flow assays (LFAs) has emerged as an attractive diagnostic platform. However, detecting small molecules such as cortisol using LFAs is challenging due to limited binding sites and weak signal generation. Here, we report the development of cortisol-specific aptamer-based probes and a paper-based origami preconcentrator (POP) to amplify the probe signal. The cortisol-specific aptamers were conjugated onto gold nanoparticles and hybridized with signal probes to create the cortisol-specific signal-on probe. POP, consisting of patterned layers with convergent wicking zones, induces electrokinetic preconcentration of the released signaling probes. By integrating cortisol-selective aptamer-based probes and POP, we accurately diagnosed cortisol levels within 30 min of signal probe incubation, followed by 10 min of preconcentration. Our sensor was able to detect cortisol levels in the range of 25–1000 ng/mL, with typical cortisol levels in plasma ranging from 40 to 250 ng/mL falling within this range. The successful detection of the wide range of cortisol samples using this approach highlights the potential of this platform as a point-of-care testing tool, particularly for lateral flow assay-based detection of small molecules like cortisol. Our approach offers a convenient and reliable method of cortisol level testing with a portable and accessible diagnosis device.
Date issued
2023-09-21
URI
https://hdl.handle.net/1721.1/153263
Department
Massachusetts Institute of Technology. Department of Electrical Engineering and Computer Science
Publisher
The Korean BioChip Society (KBCS)
Citation
Lee, N.E., Hong, J.H., Lee, S. et al. Integration of an Aptamer-Based Signal-On Probe and a Paper-Based Origami Preconcentrator for Small Molecule Biomarkers Detection. BioChip J 17, 439–446 (2023).
Version: Author's final manuscript

Collections
  • MIT Open Access Articles

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

My Account

Login

Statistics

OA StatisticsStatistics by CountryStatistics by Department
MIT Libraries
PrivacyPermissionsAccessibilityContact us
MIT
Content created by the MIT Libraries, CC BY-NC unless otherwise noted. Notify us about copyright concerns.