Characterization of the image plate multi-scan response to mono-energetic x-rays

Author(s)
Cufari, M; Vanderloo, N; Buschmann, BI; DeVault, A; Foo, BC; Vargas, J; Dannhoff, SG; Evans, TE; Johnson, TM; Kunimune, J; Lawrence, Y; Pearcy, JA; Reichelt, BL; Russell, L; Wink, CW; Gatu Johnson, M; Petrasso, RD; Frenje, JA; ... Show more Show less
Thumbnail
DownloadPublished version (4.424Mb)
Publisher with Creative Commons License

Publisher with Creative Commons License

Creative Commons Attribution

Terms of use
Creative Commons Attribution https://creativecommons.org/licenses/by/4.0/
Metadata
Show full item record
Abstract
Image plates (IPs), or phosphor storage screens, are a technology employed frequently in inertial confinement fusion (ICF) and high energy density plasma (HEDP) diagnostics because of their sensitivity to many types of radiation, including, x rays, protons, alphas, beta particles, and neutrons. Prior studies characterizing IPs are predicated on the signal level remaining below the scanner saturation threshold. Since the scanning process removes some signal from the IP via photostimulated luminescence, repeatedly scanning an IP can bring the signal level below the scanner saturation threshold. This process, in turn, raises concerns about the signal response of IPs after an arbitrary number of scans and whether such a process yields, for example, a constant ratio of signal between the nth and n + 1st scan. Here, the sensitivity of IPs is investigated when scanned multiple times. It is demonstrated that the ratio of signal decay is not a constant with the number of scans and that the signal decay depends on the x-ray energy. As such, repeatedly scanning an IP with a mixture of signal types (e.g., x ray, neutron, and protons) enables ICF and HEDP diagnostics employing IPs to better isolate a particular signal type.
Date issued
2024-09-24
URI
https://hdl.handle.net/1721.1/165058
Department
Massachusetts Institute of Technology. Plasma Science and Fusion Center
Journal
Review of Scientific Instruments
Publisher
AIP Publishing
Citation
M. Cufari, N. Vanderloo, B. I. Buschmann, A. DeVault, B. C. Foo, J. Vargas, S. G. Dannhoff, T. E. Evans, T. M. Johnson, J. Kunimune, Y. Lawrence, J. A. Pearcy, B. L. Reichelt, L. Russell, C. W. Wink, M. Gatu Johnson, R. D. Petrasso, J. A. Frenje; Characterization of the image plate multi-scan response to mono-energetic x-rays. Rev. Sci. Instrum. 1 September 2024; 95 (9): 093535.
Version: Final published version

Collections
  • MIT Open Access Articles

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

My Account

Login

Statistics

OA StatisticsStatistics by CountryStatistics by Department
MIT Libraries
PrivacyPermissionsAccessibilityContact us
MIT
Content created by the MIT Libraries, CC BY-NC unless otherwise noted. Notify us about copyright concerns.