Show simple item record

dc.contributor.advisorJames L. Terry.en_US
dc.contributor.authorBoswell, C. J. (Christopher James), 1974-en_US
dc.contributor.otherMassachusetts Institute of Technology. Dept. of Nuclear Engineering.en_US
dc.date.accessioned2005-05-17T14:37:28Z
dc.date.available2005-05-17T14:37:28Z
dc.date.copyright2003en_US
dc.date.issued2003en_US
dc.identifier.urihttp://hdl.handle.net/1721.1/16600
dc.descriptionThesis (Ph. D.)--Massachusetts Institute of Technology, Dept. of Nuclear Engineering, 2003.en_US
dc.descriptionIncludes bibliographical references (p. 155-161).en_US
dc.descriptionThis electronic version was submitted by the student author. The certified thesis is available in the Institute Archives and Special Collections.en_US
dc.description.abstractThis dissertation reports on the development of a diagnostic visible imaging system on the Alcator C-Mod tokamak and the results from that system. The dissertation asserts the value of this system as a qualitative and quantitative diagnostic for magnetically confined plasmas. The visible imaging system consists of six CCD cameras, absolutely calibrated and filtered for specific spectral ranges. Two of these cameras view the divertor region tangentially, two view RF antenna structures and two are used for a wide-angle survey of the vacuum vessel. The divertor viewing cameras are used to generate two-dimensional emissivity profiles using tomography. Three physics issues have been addressed using the visible imaging system: 1) Using two-dimensional emissivity profiles of Da, volumetric recombination rate profiles have been measured and found to have a structure that depends on a poloidal temperature gradient in the outer scrape-off-layer. 2) A camera viewing the inner wall tangentially was used to measure Da emission profiles. A sharp break in slope of the radial density profile was found at the location of the secondary separatrix near the inner wall by using these profiles and a kinetic model of the neutrals. 3) Two-dimensional emissivity profiles of visible continuum (420-430nm) have been measured and found to be an order of magnitude too large when compared to expected levels from electron-ion bremsstrahlung and radiative recombination. Several atomic and molecular processes have been considered to explain the enhanced continuum. However, none of the considered processes could explain the continuum level without particle densities inconsistent with current modeling efforts.en_US
dc.description.abstract(cont.) The visible imaging system was also used in identifying the causes of impurity injections during discharges, in identifying the failure of invessel components, and as a monitor of vessel and plasma conditions. Both the physics results and the operational benefits of the visible imaging system show that the system is a valuable quantitative and qualitative diagnostic.en_US
dc.description.statementofresponsibilityby Christopher James Boswell.en_US
dc.format.extent161 p.en_US
dc.format.extent14044093 bytes
dc.format.extent14043561 bytes
dc.format.mimetypeapplication/pdf
dc.format.mimetypeapplication/pdf
dc.language.isoengen_US
dc.publisherMassachusetts Institute of Technologyen_US
dc.rightsM.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.en_US
dc.rights.urihttp://dspace.mit.edu/handle/1721.1/7582
dc.subjectNuclear Engineering.en_US
dc.titleVisible spectroscopic imaging on the Alcator C-Mod tokamaken_US
dc.typeThesisen_US
dc.description.degreePh.D.en_US
dc.contributor.departmentMassachusetts Institute of Technology. Department of Nuclear Engineeringen_US
dc.contributor.departmentMassachusetts Institute of Technology. Department of Nuclear Science and Engineering
dc.identifier.oclc55011134en_US


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record