Show simple item record

dc.contributor.advisorWim Vanduffel.en_US
dc.contributor.authorKhachaturian, Mark Haig, 1979-en_US
dc.contributor.otherMassachusetts Institute of Technology. Dept. of Nuclear Engineering.en_US
dc.date.accessioned2005-05-19T15:43:33Z
dc.date.available2005-05-19T15:43:33Z
dc.date.copyright2003en_US
dc.date.issued2003en_US
dc.identifier.urihttp://hdl.handle.net/1721.1/17030
dc.descriptionThesis (S.M.)--Massachusetts Institute of Technology, Dept. of Nuclear Engineering, 2003.en_US
dc.descriptionIncludes bibliographical references (p. 40).en_US
dc.descriptionThis electronic version was submitted by the student author. The certified thesis is available in the Institute Archives and Special Collections.en_US
dc.description.abstractFunctional magnetic resonance imaging (fMRI) has been very useful in helping neuroscientists map the brain. One tool to investigate the interactions between brain regions is to disable a small region in the brain, and look at the functional consequences of this (reversible) inactivation upon regions anatomically connected to the inactivated site. A number of issues need to be resolved before the reversible cooling technique can be used in fMRI studies. The solutions to a number of problems directly related to using reversible inactivation by cooling in conjunction with fMRI experiments on monkey brains are presented in this thesis. Specifically, these include (1) designing a cooling system and cooling probe capable of reversibly cooling the surface cortex of the monkey's brain, (2) develop or use an existing method to measure the temperature distribution with the MR-scanner, and (3) design and construct a coil (phase array) that will be used to obtain temperature and fMRI data at the highest resolution possible. A cooling system and coolant probe were designed capable of changing the temperature of the surface cortex from 37 oC to 20 oC. The Proton Resonance Frequency Shift method, which calculates the temperature based on the phase change between two images, was used to measure the temperature distribution inside an object using an fMRI sequence similar to the one that will be used in the actual experiment. The method was tested and showed an accuracy of ± 0.6 oC as compared with concurrent thermocouple measurements when adjusted for phase drift. A precision of ± 0.15 oC was found at a resolution of 2.1 x 2.1 x 1.0 mm3. A phase array head coil was designed with superior imaging qualities to the current single coil. An increase of SNR from 40 to 52 was observed in the image (30% increase) as compared with the theoretical calculated increase of 70%.en_US
dc.description.statementofresponsibilityby Mark Haig Khachaturian.en_US
dc.format.extent51 p.en_US
dc.format.extent1155448 bytes
dc.format.extent2427367 bytes
dc.format.mimetypeapplication/pdf
dc.format.mimetypeapplication/pdf
dc.language.isoengen_US
dc.publisherMassachusetts Institute of Technologyen_US
dc.rightsM.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.en_US
dc.rights.urihttp://dspace.mit.edu/handle/1721.1/7582
dc.subjectNuclear Engineering.en_US
dc.titleSolutions to various problems in reversible cooling fMRI studiesen_US
dc.title.alternativeSolutions to various problems in reversible cooling functional magnetic resonance imaging studiesen_US
dc.typeThesisen_US
dc.description.degreeS.M.en_US
dc.contributor.departmentMassachusetts Institute of Technology. Department of Nuclear Engineeringen_US
dc.contributor.departmentMassachusetts Institute of Technology. Department of Nuclear Science and Engineering
dc.identifier.oclc54496077en_US


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record