Show simple item record

dc.contributor.advisorJack L. Kerrebrock.en_US
dc.contributor.authorTownsend, Jessica Leeen_US
dc.contributor.otherMassachusetts Institute of Technology. Dept. of Aeronautics and Astronautics.en_US
dc.date.accessioned2005-06-02T18:50:46Z
dc.date.available2005-06-02T18:50:46Z
dc.date.copyright2004en_US
dc.date.issued2004en_US
dc.identifier.urihttp://hdl.handle.net/1721.1/17831
dc.descriptionThesis (Ph. D.)--Massachusetts Institute of Technology, Dept. of Aeronautics and Astronautics, 2004.en_US
dc.descriptionPage 148 blank.en_US
dc.descriptionIncludes bibliographical references (p. 145-147).en_US
dc.description.abstractA new method of turbine blade cooling, the Return Flow Cascade, has been developed in which vaporization of a liquid metal such as potassium is used to maintain the blade surface at a nearly uniform temperature. Turbine blades cooled using this technology have lower blade temperature levels compared to that available with conventional air cooling, potentially resulting in higher firing temperatures or a choice of a wider range of materials for the hot gas path. The detailed operation of the Return Flow Cascade is described including fluid mechanic and heat transfer phenomena that occur at high heat flux and gravitational acceleration levels characteristic of modern gas turbine engines. The performance limits of the Return Flow Cascade are identified by the development of a theoretical model that estimates the performance of the system for a range of operating conditions found in the experimental test rig and in an actual gas turbine engine. These limits include vapor choking in the internal blade passages, pool boiling limits in the blade, and surface tension restriction of liquid flow. Experimental results are presented from testing in the Rotating Heat Transfer Rig at the Massachusetts Institute of Technology. An infrared detector capable of high scan rates was used to fully map the temperature distribution of a single, heated, rotating turbine blade. The blade surface temperature maps show that the Return Flow Cascade works as designed by enforcing a nearly constant temperature over the surface of the blade. Cascade initiation limits predicted by the internal vapor choking model are in good agreement with the test data.en_US
dc.description.statementofresponsibilityby Jessica L. Townsend.en_US
dc.format.extent148 p.en_US
dc.format.extent7448787 bytes
dc.format.extent7465247 bytes
dc.format.mimetypeapplication/pdf
dc.format.mimetypeapplication/pdf
dc.language.isoengen_US
dc.publisherMassachusetts Institute of Technologyen_US
dc.rightsM.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.en_US
dc.rights.urihttp://dspace.mit.edu/handle/1721.1/7582
dc.subjectAeronautics and Astronautics.en_US
dc.titleExperimental evaluation and modeling of a turbine blade with potassium evaporative coolingen_US
dc.typeThesisen_US
dc.description.degreePh.D.en_US
dc.contributor.departmentMassachusetts Institute of Technology. Department of Aeronautics and Astronautics
dc.identifier.oclc56569835en_US


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record